1104.4.3 Musical Risers
JUMP TO FULL CODE CHAPTER
An accessible route shall be provided to the main floor level and to at least one riser level of built-in or fixed riser assemblies designed for instrumental or choral use.
Exception: An accessible route is not required to risers where performers are positioned on the main floor level at the base of the risers.
Related Code Sections
1104.4.3 Accessibility, Musical Risers
An accessible route shall be provided to the main floor level and to at least one riser level of built-in or fixed riser assemblies designed ...
2020 Minnesota Building Code > 11 Accessibility > 1104 Accessible Route > 1104.4 Multistory Buildings and Facilities > 1104.4.3 Musical Risers
1104.4.3 Of the 2012 IBC With Minnesota Amendments, Musical Risers
An accessible route shall be provided to the main floor level and to at least one riser level of built-in or fixed riser assemblies designed ...
Minnesota Accessibility Code 2015 > 11 Of the 2012 IBC With Minnesota Amendments > 1104 Accessible Route > 1104.4 Multilevel Buildings and Facilities > 1104.4.3 Musical Risers
1028.11.2 Means of Egress, Risers
Where the gradient of aisle stairs is to be the same as the gradient of adjoining seating areas, the riser height shall not be less than 4 inches ...
Minnesota Building Code 2015 > 10 Means of Egress > 1028 Assembly > 1028.11 Assembly Aisle Walking Surfaces > 1028.11.2 Risers
1028.11.2 Means of Egress, Risers
Where the gradient of aisle stairs is to be the same as the gradient of adjoining seating areas, the riser height shall not be less than 4 inches ...
Minnesota Fire Code 2015 > 10 Means of Egress > 1028 Assembly > 1028.11 Assembly Aisle Walking Surfaces > 1028.11.2 Risers
1029.14.2.2 Means of Egress, Risers
Where the gradient of stepped aisles is to be the same as the gradient of adjoining seating areas, the riser height shall be not less than 4 inches ...
2020 Minnesota Building Code > 10 Means of Egress > 1029 Assembly > 1029.14 Assembly Aisle Walking Surfaces > 1029.14.2 Stepped Aisles > 1029.14.2.2 Risers