702.7 Municipal Reclaimed Water
JUMP TO FULL CODE CHAPTER
Where required by Table 302.1 and where municipal reclaimed water is accessible and allowed for such use by the laws, rules and ordinances applicable in the jurisdiction, it shall be supplied to water closets, water-supplied urinals, water-supplied trap primers and applicable industrial uses. A municipal reclaimed water supply shall be deemed accessible where the supply is not greater that 150 percent of the distance that the potable water supply is from the lot boundary or the supply is within 100 feet (30.5 m) of a potable water supply that serves the lot.
Related Code Sections
702.7 Water Resource Conservation, Quality and Efficiency, Municipal Reclaimed Water
Where required by Table 302.1 and where municipal reclaimed water is accessible and allowed for such use by the laws, rules and ordinances applicable ...
Green Construction Code 2012 of Maryland > 7 Water Resource Conservation, Quality and Efficiency > 702 Fixtures, Fittings, Equipment and Appliances > 702.7 Municipal Reclaimed Water
703.8.2 Water Resource Conservation, Quality and Efficiency, Water Sources
Where suitable alternate onsite nonpotable water or municipal reclaimed water is available, makeup water supplies to the recirculation system of wet ...
Green Construction Code 2012 of Maryland > 7 Water Resource Conservation, Quality and Efficiency > 703 HVAC Systems and Equipment > 703.8 Wet-Hood Exhaust Scrubber Systems > 703.8.2 Water Sources
404.1.1 Site Development and Land Use, Water for Outdoor Landscape Irrigation
in accordance with Section 404.1.2 or, where permitted by State regulation or local ordinances, the system shall be supplied by municipal reclaimed ...
Green Construction Code 2012 of Maryland > 4 Site Development and Land Use > 404 Landscape Irrigation and Outdoor Fountains > 404.1 Landscape Irrigation Systems > 404.1.1 Water for Outdoor Landscape Irrigation
707.11.7.3 Water Resource Conservation, Quality and Efficiency, Makeup Water
Where an uninterrupted supply is required for the intended application, potable or municipally supplied reclaimed or recycled water shall be provided ...
Green Construction Code 2012 of Maryland > 7 Water Resource Conservation, Quality and Efficiency > 707 Rainwater Collection and Distribution Systems > 707.11 Rainwater Catchment and Collection Systems > 707.11.7 Storage Tank > 707.11.7.3 Makeup Water
708.12.6.4 Water Resource Conservation, Quality and Efficiency, Makeup Water
Where an uninterrupted supply of makeup water is required for the intended application, potable or municipally supplied reclaimed/recycled water ...
Green Construction Code 2012 of Maryland > 7 Water Resource Conservation, Quality and Efficiency > 708 Gray Water Systems > 708.12 Gray Water Systems > 708.12.6 Storage Tank > 708.12.6.4 Makeup Water