1107.7.2 Multistory Units
JUMP TO FULL CODE CHAPTER
A multistory dwelling unit or sleeping unit that is not provided with elevator service is not required to be a Type B unit. Where a multistory unit is provided with external elevator service to only one floor, the floor provided with elevator service shall be the primary entry to the unit, shall comply with the requirements for a Type B unit and, where provided within the unit, a living area, a kitchen and a toilet facility shall be provided on that floor.
Related Code Sections
1107.7.2 Accessibility, Multistory Units
A multistory dwelling unit or sleeping unit that is not provided with elevator service is not required to be a Type B unit . Where a multistory ...
Building Code 2018 of Illinois > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.7 General Exceptions > 1107.7.2 Multistory Units
1108.7.2 Accessibility, Multistory Units
A multistory dwelling unit or sleeping unit that is not provided with elevator service is not required to be a Type B unit . Where a multistory ...
Building Code 2021 of Illinois > 11 Accessibility > 1108 Dwelling Units and Sleeping Units > 1108.7 General Exceptions > 1108.7.2 Multistory Units
1006.3.4 Means of Egress, Single Exits
-story or multistory dwelling units shall be permitted to have a single exit or access to a single exit from the dwelling unit provided ...
Building Code 2021 of Illinois > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.4 Single Exits
17.4.5.4 Installation Requirements for Hanging and Support of System Piping, Multistory Buildings
In multistory buildings, riser supports shall be provided at the lowest level, at each alternate level above, above and below offsets, and at the top ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 17 Installation Requirements for Hanging and Support of System Piping > 17.4* Installation of Pipe Hangers > 17.4.5 Support of Risers > 17.4.5.4 Multistory Buildings
1104.4 Accessibility, Multistory Buildings and Facilities
Structures with four or more dwelling units. Stories , mezzanines or occupied roofs that do not contain accessible elements or other ...
Building Code 2021 of Illinois > 11 Accessibility > 1104 Accessible Route > 1104.4 Multistory Buildings and Facilities