504.3.13 Multistory Height Measurement
JUMP TO FULL CODE CHAPTER
For multistory installations, available total height (H) for each segment of the system shall be the vertical distance between the highest draft hood outlet or flue collar entering that segment and the centerline of the next higher interconnection tee.
Related Code Sections
504.3.13 Chimneys and Vents, Multistory Height Measurement
For multistory installations, available total height ( H ) for each segment of the system shall be the vertical distance between the highest draft ...
Fuel Gas Code 2018 of Kansas > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.3 Application of Multiple Appliance Vent Tables 504.3(1) Through 504.3(7) > 504.3.13 Multistory Height Measurement
801.19 Chimneys and Vents, Multistory Prohibited
Common venting systems for appliances located on more than one floor level shall be prohibited, except where all of the appliances served ...
9.2.5.4 Hanging, Bracing, and Restraint of System Piping, Multistory Buildings
In multistory buildings, riser supports shall be provided at the lowest level, at each alternate level above, above and below offsets, and at the top ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 9 Hanging, Bracing, and Restraint of System Piping > 9.2* Installation of Pipe Hangers > 9.2.5 Support of Risers > 9.2.5.4 Multistory Buildings
506.2.3 General Building Heights and Areas, Single-Occupancy, Multistory Buildings
The allowable area of a single-occupancy building with more than one story above grade plane shall be determined in accordance with Equation 5-2 ...
Building Code 2018 of Kansas > 5 General Building Heights and Areas > 506 Building Area > 506.2 Allowable Area Determination > 506.2.3 Single-Occupancy, Multistory Buildings
503.6.11.2 Chimneys and Vents, Sizing
be in accordance with Table 504.3(1), provided that: The available total height ( H ) for each segment of a multistory venting system ...
Fuel Gas Code 2018 of Kansas > 5 Chimneys and Vents > 503 (IFGS) Venting of Appliances > 503.6 Gas Vents > 503.6.11 Gas Vents Serving Appliances on More Than One Floor > 503.6.11.2 Sizing