// CODE SNIPPET
3109.6.2.3 Multiple Main Drains
JUMP TO FULL CODE CHAPTER
When two or more main drains are installed, a minimum of two suction outlets per pump with drain cover centers at least 3 feet apart must be provided. If the minimum spacing distance or two suction per pump requirement cannot be met, the drain shall be considered a single main drain.
Related Code Sections
3109.6.2.3 Special Construction, Multiple Main Drains
When two or more main drains are installed, a minimum of two suction outlets per pump with drain cover centers at least 3 feet apart must be provided ...
2010 Building Code of NY > 31 Special Construction > 3109 Swimming Pool Enclosures and Safety Devices > 3109.6 Entrapment Protection > 3109.6.2 Entrapment Avoidance > 3109.6.2.3 Multiple Main Drains
1103.1 Storm Drainage, Main Trap
branch serving each conductor, or a single trap shall be installed in the main storm drain just before its connection with the combined building ...
1103.1 Storm Drainage, Main Trap
branch serving each conductor, or a single trap shall be installed in the main storm drain just before its connection with the combined building ...
25.2.3.4 Systems Acceptance, Main Drain Valves
The main drain valve shall be opened and remain open until the system pressure stabilizes ...
Standard for the Installation of Sprinkler Systems 2016 of New York State > 25 Systems Acceptance > 25.2 Acceptance Requirements > 25.2.3 System Operational Tests > 25.2.3.4 Main Drain Valves
25.2.3.4 Systems Acceptance, Main Drain Valves
The main drain valve shall be opened and remain open until the system pressure stabilizes ...
Standard for the Installation of Sprinkler Systems 2013 of New York State > 25 Systems Acceptance > 25.2 Acceptance Requirements > 25.2.3 System Operational Tests > 25.2.3.4 Main Drain Valves