• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

6104.4 Multiple LP-gas Container Installations

Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6104 Location of LP-gas Containers > 6104.4 Multiple LP-gas Container Installations
JUMP TO FULL CODE CHAPTER
Multiple LP-gas container installations with a total water storage capacity of more than 180,000 gallons (681 300 L) [150,000-gallon (567 750 L) LP-gas capacity] shall be subdivided into groups containing not more than 180,000 gallons (681 300 L) in each group. Such groups shall be separated by a distance of not less than 50 feet (15 240 mm), unless the containers are protected in accordance with one of the following:
  1. Mounded in an approved manner.
  2. Protected with approved insulation on areas that are subject to impingement of ignited gas from pipelines or other leakage.
  3. Protected by fire walls of approved construction.
  4. Protected by an approved system for application of water as specified in Table 6.5.1.2 of NFPA 58.
  5. Protected by other approved means.
Where one of these forms of protection is provided, the separation shall be not less than 25 feet (7620 mm) between LP-gas container groups.

Related Code Sections


6104.4 Liquefied Petroleum Gases, Multiple LP-gas Container Installations
Multiple LP-gas container installations with a total water storage capacity of more than 180,000 gallons (681.3 kL) [150,000-gallon (567.8 kL) LP-gas ...
Fire Code 2021 of Colorado > 61 Liquefied Petroleum Gases > 6104 Location of LP-gas Containers > 6104.4 Multiple LP-gas Container Installations
6104.4 Liquefied Petroleum Gases, Multiple LP-gas Container Installations
Multiple LP-gas container installations with a total water storage capacity of more than 180,000 gallons (681 300 L) [150,000-gallon (567 750 L) LP ...
Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6104 Location of LP-gas Containers > 6104.4 Multiple LP-gas Container Installations
105.5.29 Scope and Administration, LP-gas
An operational permit is required for: Storage and use of LP-gas. Exception: A permit is not required for individual containers with a 500 ...
Fire Code 2021 of Colorado > 1 Scope and Administration > 105 Permits > 105.5 Required Operational Permits > 105.5.29 LP-gas
105.6.27 Scope and Administration, LP-gas
An operational permit is required for: Storage and use of LP-gas. Exception: A permit is not required for individual containers with a 500 ...
Fire Code 2018 of Colorado > 1 Scope and Administration > 105 Permits > 105.6 Required Operational Permits > 105.6.27 LP-gas
Section 6103 Liquefied Petroleum Gases, Installation of Equipment
LP-gas equipment shall be installed in accordance with the International Fuel Gas Code and NFPA 58, except as otherwise provided in this chapter ...
Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6103 Installation of Equipment
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING