G2428.2.6 (504.2.6) Multiple Input Rate Appliances
JUMP TO FULL CODE CHAPTER
For appliances with more than one input rate, the minimum vent capacity (FAN Min) determined from the tables shall be less than the lowest appliance input rating, and the maximum vent capacity (FAN Max/NAT Max) determined from the tables shall be greater than the highest appliance rating input.
Related Code Sections
G2428.2.6 Fuel Gas, (504.2.6) Multiple Input Rate Appliances
For appliances with more than one input rate, the minimum vent capacity (FAN Min) determined from the tables shall be less than the lowest ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2428 (504) Sizing of Category I Appliance Venting Systems > G2428.2 (504.2) Application of Single-Appliance Vent Tables G2428.2(1) and G2428.2(2) > G2428.2.6 (504.2.6) Multiple Input Rate Appliances
504.2.6 Chimneys and Vents, Multiple Input Rate Appliances
For appliances with more than one input rate, the minimum vent capacity (FAN Min) determined from the tables shall be less than the lowest appliance ...
Fuel Gas Code 2018 of Kansas > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.2 Application of Single-Appliance Vent Tables 504.2(1) Through 504.2(6) > 504.2.6 Multiple Input Rate Appliances
621.3 Specific Appliances, Input Rating
Unvented room heaters shall not have an input rating in excess of 40,000 Btu/h (11.7 kW) ...
Fuel Gas Code 2018 of Kansas > 6 Specific Appliances > 621 (IFGC) Unvented Room Heaters > 621.3 Input Rating
G2428.3.10 Fuel Gas, (504.3.10) High-Altitude Installations
Sea-level input ratings shall be used when determining maximum capacity for high-altitude installation. Actual input, derated for altitude, shall ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2428 (504) Sizing of Category I Appliance Venting Systems > G2428.3 (504.3) Application of Multiple Appliance Vent Tables G2428.3(1) Through G2428.3(4) > G2428.3.10 (504.3.10) High-Altitude Installations
504.3.20 Chimneys and Vents, Chimney and Vent Location
than one appliance is draft hood equipped. The combined appliance input rating is less than the maximum capacity given by Table 504.3(6a) for NAT+NAT ...
Fuel Gas Code 2018 of Kansas > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.3 Application of Multiple Appliance Vent Tables 504.3(1) Through 504.3(7) > 504.3.20 Chimney and Vent Location