1004.3 Multiple Function Occupant Load
JUMP TO FULL CODE CHAPTER
Where an area under consideration contains multiple functions having different occupant load factors, the design occupant load for such area shall be based on the floor area of each function calculated independently.
Related Code Sections
1004.3 Means of Egress, Multiple Function Occupant Load
Where an area under consideration contains multiple functions having different occupant load factors, the design occupant load for such area shall ...
Building Code 2018 of Illinois > 10 Means of Egress > 1004 Occupant Load > 1004.3 Multiple Function Occupant Load
1004.3 Means of Egress, Multiple Function Occupant Load
Where an area under consideration contains multiple functions having different occupant load factors, the design occupant load for such area shall ...
Building Code 2021 of Illinois > 10 Means of Egress > 1004 Occupant Load > 1004.3 Multiple Function Occupant Load
29.12 Single- And Multiple-Station Alarms and Household Signaling Systems, Optional Functions
of occupants or others of the activation of intrusion (burglar alarm) sensors Any other function, safety related or not, that could share components ...
National Fire Alarm and Signaling Code 2019 of Illinois > 29 Single- And Multiple-Station Alarms and Household Signaling Systems > 29.12 Optional Functions
C408.3.1 [CE] Commercial Energy Efficiency, Functional Testing
documents and manufacturer's instructions. Functional testing shall be in accordance with Sections C408.3.1.1 through C408.3.1.3 for the applicable control ...
2018 Illinois Energy Conservation Code Standards for Privately Funded Commercial Facilities and Standards for Residential Buildings > 4 [CE] Commercial Energy Efficiency > C408 Maintenance Information and System Commissioning > C408.3 Functional Testing of Lighting Controls > C408.3.1 Functional Testing
903.2.1.7 Fire Protection and Life Safety Systems, Multiple Fire Areas
An automatic sprinkler system shall be provided where multiple fire areas of Group A-1, A-2, A-3 or A-4 occupancies share exit or exit access ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.1 Group A > 903.2.1.7 Multiple Fire Areas