• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.961(b)(4) Multiple Crews

OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.961 Deenergizing Lines and Equipment for Employee Protection > 1926.961(b) General > 1926.961(b)(4) Multiple Crews
JUMP TO FULL CODE CHAPTER
If two or more crews will be working on the same lines or equipment, then:

1926.961(b)(4)(i)

The crews shall coordinate their activities under this section with a single employee in charge of the clearance for all of the crews and follow the requirements of this section as if all of the employees formed a single crew, or

1926.961(b)(4)(ii)

Each crew shall independently comply with this section and, if there is no system operator in charge of the lines or equipment, shall have separate tags and coordinate deenergizing and reenergizing the lines and equipment with the other crews.

Related Code Sections


1926.961(b)(4) Electric Power Transmission and Distribution, Multiple Crews
If two or more crews will be working on the same lines or equipment ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.961 Deenergizing Lines and Equipment for Employee Protection > 1926.961(b) General > 1926.961(b)(4) Multiple Crews
1926.1404(d) Cranes & Derricks in Construction, Crew Instructions
Before commencing assembly/disassembly operations, the A/D director must ensure that the crew members understand all of the following ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1404 Assembly/Disassembly--General Requirements (Applies to All Assembly and Disassembly Operations) > 1926.1404(d) Crew Instructions
1926.905(l) Blasting and the Use of Explosives,
When loading a long line of holes with more than one loading crew, the crews shall be separated by practical distance consistent with efficient ...
OSHA 1926 Construction > U Blasting and the Use of Explosives > 1926.905 Loading of Explosives or Blasting Agents > 1926.905(l)
1926.1404(e)(2) Cranes & Derricks in Construction,
Where the operator knows that a crew member went to a location covered by paragraph (e)(1) of this section, the operator must not move any part ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1404 Assembly/Disassembly--General Requirements (Applies to All Assembly and Disassembly Operations) > 1926.1404(e) Protecting Assembly/Disassembly Crew Members Out of Operator View > 1926.1404(e)(2)
1926.961 Electric Power Transmission and Distribution, Deenergizing Lines and Equipment for Employee Protection
, the employer shall designate one employee in the crew to be in charge of the clearance and shall comply with all of the requirements of paragraph (c ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.961 Deenergizing Lines and Equipment for Employee Protection
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING