• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1108.2.4.1 Multilevel Assembly Seating Areas

NYC Building Code 2008 > 11 Accessibility > 1108 Special Occupancies > 1108.2 Assembly Area Seating > 1108.2.4 Dispersion of Wheelchair Spaces > 1108.2.4.1 Multilevel Assembly Seating Areas
JUMP TO FULL CODE CHAPTER
In multilevel assembly seating areas, wheelchair spaces shall be provided on the main floor level and on each additional floor or mezzanine levels. Wheelchair spaces shall be provided in each luxury box, club box and suite within assembly facilities
Exceptions:
  1. In multilevel assembly spaces utilized for worship services, where the second floor or mezzanine level contains 25 percent or less of the total seating capacity, all wheelchair space clusters shall be permitted to be located on the main level.
  2. In multilevel assembly seating where the second floor or mezzanine level provides 25 percent or less of the total seating capacity and 300 or fewer seats, wheelchair space clusters shall be permitted to all be located on the main level.

Related Code Sections


1108.2.4.1 Accessibility, Multilevel Assembly Seating Areas
In multilevel assembly seating areas, wheelchair spaces shall be provided on the main floor level and on each additional floor or mezzanine levels ...
NYC Building Code 2008 > 11 Accessibility > 1108 Special Occupancies > 1108.2 Assembly Area Seating > 1108.2.4 Dispersion of Wheelchair Spaces > 1108.2.4.1 Multilevel Assembly Seating Areas
1108.2.4 Accessibility, Dispersion of Wheelchair Spaces in Multilevel Assembly Seating Areas
In multilevel assembly seating areas, wheelchair spaces shall be provided on the main floor level and on one of each two additional floor ...
NYC Building Code 2022 > 11 Accessibility > 1108 Special Occupancies > 1108.2 Assembly Area Seating > 1108.2.4 Dispersion of Wheelchair Spaces in Multilevel Assembly Seating Areas
1108.2.4 Accessibility, Dispersion of Wheelchair Spaces in Multilevel Assembly Seating Areas
In multilevel assembly seating areas, wheelchair spaces shall be provided on the main floor level and on one of each two additional floor ...
NYC Building Code 2014 > 11 Accessibility > 1108 Special Occupancies > 1108.2 Assembly Area Seating > 1108.2.4 Dispersion of Wheelchair Spaces in Multilevel Assembly Seating Areas
Section 1102 Accessibility, Definitions
WORK AREA. FACILITY. HALL CALL CONSOLE. INTENDED TO BE OCCUPIED AS A RESIDENCE. MULTILEVEL ASSEMBLY SEATING. MULTISTORY UNIT. PRIMARY ...
NYC Building Code 2022 > 11 Accessibility > 1102 Definitions
1108.2 Accessibility, Assembly Area Seating
In multilevel assembly seating areas, wheelchair spaces shall ...
NYC Building Code 2014 > 11 Accessibility > 1108 Special Occupancies > 1108.2 Assembly Area Seating
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING