1926.452(q) Multi-Point Adjustable Suspension Scaffolds, Stonesetters' Multi-Point Adjustable Suspension Scaffolds, and Masons' Multi-Point Adjustable Suspension Scaffolds
JUMP TO FULL CODE CHAPTER
When two or more scaffolds are used they shall not be bridged one to another unless they are designed to be bridged, the bridge connections are articulated, and the hoists are properly sized.
If bridges are not used, passage may be made from one platform to another only when the platforms are at the same height and are abutting.
Scaffolds shall be suspended from metal outriggers, brackets, wire rope slings, hooks, or means that meet equivalent criteria (e.g., strength, durability).
Related Code Sections
1926.452(q)(1) Scaffolds,
When two or more scaffolds are used they shall not be bridged one to another unless they are designed to be bridged, the bridge connections ...
OSHA 1926 Construction > L Scaffolds > 1926.452 Additional Requirements Applicable to Specific Types of Scaffolds > 1926.452(q) Multi-Point Adjustable Suspension Scaffolds, Stonesetters' Multi-Point Adjustable Suspension Scaffolds, and Masons' Multi-Point Adjustable Suspension Scaffolds > 1926.452(q)(1)
Subpart L Scaffolds, App A - Scaffold Specifications
scaffolds.
Single-point adjustable suspension scaffolds.
Two-point adjustable suspension scaffolds.
Stonesetters' multi-point adjustable ...
1926.451(d)(3)(i) Scaffolds,
, that the supporting surfaces are capable of supporting the loads to be imposed. In addition, masons' multi-point adjustable suspension scaffold connections shall ...
OSHA 1926 Construction > L Scaffolds > 1926.451 General Requirements > 1926.451(d) Criteria for Suspension Scaffolds > 1926.451(d)(3) > 1926.451(d)(3)(i)
1926.450(b) Scaffolds, Definitions
").
Masons' multi-point adjustable suspension scaffold means a continuous run suspension scaffold designed and used for masonry operations.
Maximum ...
OSHA 1926 Construction > L Scaffolds > 1926.450 Scope, Application and Definitions Applicable to This Subpart > 1926.450(b) Definitions
1926.451(d) Scaffolds, Criteria for Suspension Scaffolds
have their inboard ends stabilized by counterweights, except masons' multi-point adjustable suspension scaffold outrigger beams shall not be stabilized ...
OSHA 1926 Construction > L Scaffolds > 1926.451 General Requirements > 1926.451(d) Criteria for Suspension Scaffolds