• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

505.4.1 Multi-Floor Dwelling Units

NYC Fire Code 2014 > 5 Fire Operations Features > 505 Premises Identification > 505.4 Apartment, Guest Room and Stairwell Fire Emergency Markings > 505.4.1 Multi-Floor Dwelling Units
JUMP TO FULL CODE CHAPTER
The entrance door to a multi-floor dwelling unit in a Group R-1 or Group R-2 building or occupancy shall be identified on the door jamb on the public corridor side of the door by an approved fire emergency marking, not more than 12 inches (305 mm) from the bottom of the door, indicating the dwelling unit number and/or letter. In addition, every door of each such multi-floor dwelling unit that opens to a public corridor or other means of egress shall be identified on the public corridor side of the door by one or more upward or downward-pointing arrows indicating the direction(s) of the other floor(s) to which the multi-floor dwelling unit is connected.

Related Code Sections


1003.12.4.1 Dwelling Units and Sleeping Units, Clear Floor Space
A clear floor space, positioned for a forward approach to the sink, shall be provided. Knee and toe clearance complying with Section 306 shall ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1003 Type A Units > 1003.12 Kitchens and Kitchenettes > 1003.12.4 Sink > 1003.12.4.1 Clear Floor Space
1107.7.1.1 Accessibility, One Story With Type B Units Required
-2, in buildings where the lowest story containing dwelling or sleeping units is the cellar, basement, or first floor, at least one such story ...
NYC Building Code 2008 > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.7 General Exceptions > 1107.7.1 Buildings Without Elevator Service > 1107.7.1.1 One Story With Type B Units Required
1105.1.6.1 Accessibility, Dwelling Units and Sleeping Units
Entrances to multi-story dwelling or sleeping units in R-2 occupancy as provided in Section 1107.2.5 that are not on the primary entry story to the unit ...
NYC Building Code 2008 > 11 Accessibility > 1105 Accessible Entrances > 1105.1 Public Entrances > 1105.1.6 Tenant Spaces > 1105.1.6.1 Dwelling Units and Sleeping Units
1107.7.1 Accessibility, Buildings Without Elevator Service
-2, in buildings where the lowest story containing dwelling or sleeping units is the cellar, basement, or first floor, at least one such story ...
NYC Building Code 2008 > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.7 General Exceptions > 1107.7.1 Buildings Without Elevator Service
1208.3.2 Interior Environment, Dwelling Units
In a dwelling unit, at least one habitable room shall have not less than 150 square feet (13.9 m 2 ) of net floor area. Exception: Group R-1 ...
NYC Building Code 2008 > 12 Interior Environment > 1208 Interior Space Dimensions > 1208.3 Room Area > 1208.3.2 Dwelling Units
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING