507.11.2 Mounting Position
JUMP TO FULL CODE CHAPTER
Filters shall be installed at an angle of not less than 45 degrees (0.79 rad) from the horizontal and shall be equipped with a drip tray beneath the lower edge of the filters.
Related Code Sections
507.11.2 Exhaust Systems, Mounting Position
Filters shall be installed at an angle of not less than 45 degrees (0.79 rad) from the horizontal and shall be equipped with a drip tray beneath ...
Mechanical Code 2012 of Tennessee > 5 Exhaust Systems > 507 Commercial Kitchen Hoods > 507.11 Grease Filters > 507.11.2 Mounting Position
240.33 Wiring and Protection, Vertical Position
Enclosures for overcurrent devices shall be mounted in a vertical position unless that is shown to be impracticable. Circuit breaker enclosures shall ...
National Electrical Code 2017 of Tennessee > 2 Wiring and Protection > 240 Overcurrent Protection > 240.33 Vertical Position
(4) Special Occupancies, Portable Lighting Equipment
and is connected by flexible cords, as covered in 501.140, it shall be permitted to comply with 501.130(B)(1), where mounted in any position, provided that it also ...
National Electrical Code 2017 of Tennessee > 5 Special Occupancies > 501 Class I Locations > 501.130 Luminaires > (B) Class I, Division 2 > (4) Portable Lighting Equipment
520.2 Special Occupancies, Definitions
, projection, or video. Stage Lighting Hoist. A motorized lifting device that contains a mounting position for one or more luminaires, with wiring devices ...
National Electrical Code 2017 of Tennessee > 5 Special Occupancies > 520 Theaters, Audience Areas of Motion Picture and Television Studios, Performance Areas, and Similar Locations > 520.2 Definitions
1005.7.1 Means of Egress, Doors
) encroachment where:
The hardware is mounted to the side of the door facing away from the adjacent wall where the door is in the open position ...
Fire Code 2012 of Tennessee > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.7 Encroachment > 1005.7.1 Doors