1910.68(b)(10)(iii) Mounting Platform
JUMP TO FULL CODE CHAPTER
A mounting platform shall be provided in front or to one side of the uprun at the lowest landing, unless the floor level is such that the following requirement can be met: The floor or platform shall be at or above the point at which the upper surface of the ascending step completes its turn and assumes a horizontal position.
Related Code Sections
1910.68(b)(10)(iii) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Mounting Platform
A mounting platform shall be provided in front or to one side of the uprun at the lowest landing, unless the floor level is such that the following ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.68 Manlifts > 1910.68(b) General Requirements > 1910.68(b)(10) Bottom Arrangement > 1910.68(b)(10)(iii) Mounting Platform
1910.67(a) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Definitions Applicable to This Section
Any vehicle—mounted device, telescoping or articulating, or both, which is used to position personnel ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.67 Vehicle-Mounted Elevating and Rotating Work Platforms > 1910.67(a) Definitions Applicable to This Section
1910.66 Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Powered Platforms for Building Maintenance
mounted on a platform.
Guide roller means a rotating cylindrical member, operating separately or as part of a guide assembly, designed to provide ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance
1910.67(b)(1) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
in conformance with the applicable requirements of the American National Standard for "Vehicle Mounted Elevating and Rotating Work Platforms," ANSI A92.2 ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.67 Vehicle-Mounted Elevating and Rotating Work Platforms > 1910.67(b) General Requirements > 1910.67(b)(1)
1910.67(b)(2) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
Aerial lifts may be "field modified" for uses other than those intended by the manufacturer, provided the modification has been certified in writing ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.67 Vehicle-Mounted Elevating and Rotating Work Platforms > 1910.67(b) General Requirements > 1910.67(b)(2)