• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1024.2.6.1.1 Mounting Location

NYC Building Code 2014 > 10 Means of Egress > 1024 Luminous Egress Path Markings > 1024.2 Required Markings > 1024.2.6 Doors From Exit Enclosures > 1024.2.6.1 Emergency Exit Symbol > 1024.2.6.1.1 Mounting Location
JUMP TO FULL CODE CHAPTER
The vertical centerline of the sign shall be centered with the door, or shall be in that half of the door, either the right or left, that contains the latch. In case of double-doors, both doors shall be marked and the signs shall be centered with the doors. Arrows may be omitted on door-mounted signs. Door-mounted signs shall comply with Figure S101.1(1) in Appendix S.

Related Code Sections


1024.2.6.1.1 Means of Egress, Mounting Location
the latch. In case of double-doors, both doors shall be marked and the signs shall be centered with the doors. Arrows may be omitted on door-mounted ...
NYC Building Code 2014 > 10 Means of Egress > 1024 Luminous Egress Path Markings > 1024.2 Required Markings > 1024.2.6 Doors From Exit Enclosures > 1024.2.6.1 Emergency Exit Symbol > 1024.2.6.1.1 Mounting Location
1025.2.6.1.1 Means of Egress, Mounting Location
the latch. In case of double-doors, both doors shall be marked and the signs shall be centered with the doors. Arrows may be omitted on door-mounted ...
NYC Building Code 2022 > 10 Means of Egress > 1025 Luminous Egress Path Markings > 1025.2 Required Markings > 1025.2.6 Doors Within the Exit Path > 1025.2.6.1 Emergency Exit Symbol > 1025.2.6.1.1 Mounting Location
8.7.5.1.4.1 Installation Requirements,
Isolated obstructions projecting from the same wall as the one on which the sidewall sprinkler is mounted shall be located a minimum of 4 in. (100 mm ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.7 Sidewall Standard Spray Sprinklers > 8.7.5 Obstructions to Sprinkler Discharge (Standard Sidewall Spray Sprinklers) > 8.7.5.1 Performance Objective > 8.7.5.1.4 > 8.7.5.1.4.1
8.9.5.1.5 Installation Requirements, Isolated Obstructions
Isolated obstructions projecting from the same wall as the one on which the extended coverage sidewall sprinkler is mounted shall be located ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.9* Extended Coverage Sidewall Spray Sprinklers > 8.9.5 Obstructions to Sprinkler Discharge (Extended Coverage Sidewall Spray Sprinklers) > 8.9.5.1 Performance Objective > 8.9.5.1.5 Isolated Obstructions
603.3 Plumbing Elements and Facilities, Mirrors
Where mirrors are located above lavatories, a mirror shall be located over the accessible lavatory and shall be mounted with the bottom edge ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 6 Plumbing Elements and Facilities > 603 Toilet and Bathing Rooms > 603.3 Mirrors
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING