2103.2.3 Mortars for Ceramic Wall and Floor Tile
JUMP TO FULL CODE CHAPTER
Portland cement mortars for installing ceramic wall and floor tile shall comply with ANSI A108.1A and ANSI A108.1B and be of the compositions indicated in Table 2103.2.3.
CERAMIC TILE MORTAR COMPOSITIONS
LOCATION | MORTAR | COMPOSITION |
Walls | Scratchcoat | 1 cement; 1/5 hydrated lime; 4 dry or 5 damp sand |
Setting bed and leveling coat | 1 cement; 1/2 hydrated lime; 5 damp sand to 1 cement 1 hydrated lime, 7 damp sand | |
Floors | Setting bed | 1 cement; 1/10 hydrated lime; 5 dry or 6 damp sand; or 1 cement; 5 dry or 6 damp sand |
Ceilings | Scratchcoat and sand bed | 1 cement; 1/2 hydrated lime; 21/2 dry sand or 3 damp sand |
Premixed prepared Portland cement mortars, which require only the addition of water and are used in the installation of ceramic tile, shall comply with ANSI A118.1. The shear bond strength for tile set in such mortar shall be as required in accordance with ANSI A118.1. Tile set in dry-set Portland cement mortar shall be installed in accordance with ANSI A108.5.
Latex-modified Portland cement thin-set mortars in which latex is added to dry-set mortar as a replacement for all or part of the gauging water that are used for the installation of ceramic tile shall comply with ANSI A118.4. Tile set in latex-modified Portland cement shall be installed in accordance with ANSI A108.5.
Ceramic tile set and grouted with chemical-resistant epoxy shall comply with ANSI A118.3. Tile set and grouted with epoxy shall be installed in accordance with ANSI A108.6.
Chemical-resistant furan mortar and grout that are used to install ceramic tile shall comply with ANSI A118.5. Tile set and grouted with furan shall be installed in accordance with ANSI A108.8.
Water-resistant organic adhesives used for the installation of ceramic tile shall comply with ANSI A136.1. The shear bond strength after water immersion shall be not less than 40 psi (275 kPa) for Type I adhesive and not less than 20 psi (138 kPa) for Type II adhesive when tested in accordance with ANSI A136.1. Tile set in organic adhesives shall be installed in accordance with ANSI A108.4.
Portland cement grouts used for the installation of ceramic tile shall comply with ANSI A118.6. Portland cement grouts for tile work shall be installed in accordance with ANSI A108.10.
Related Code Sections
2103.2.3 Masonry, Mortars for Ceramic Wall and Floor Tile
Portland cement mortars for installing ceramic wall and floor tile shall comply with ANSI A108.1A and ANSI A108.1B and be of the compositions ...
Building Code 2021 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile
2103.2.3 Masonry, Mortars for Ceramic Wall and Floor Tile
Portland cement mortars for installing ceramic wall and floor tile shall comply with ANSI A108.1A and ANSI A108.1B and be of the compositions ...
Building Code 2018 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile
2103.2.3.7 Masonry, Portland Cement Grouts
Portland cement grouts used for the installation of ceramic tile shall comply with ANSI A118.6. Portland cement grouts for tile work shall ...
Building Code 2018 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile > 2103.2.3.7 Portland Cement Grouts
2103.2.3.5 Masonry, Modified Epoxy-Emulsion Mortar and Grout
Modified epoxy-emulsion mortar and grout that are used to install ceramic tile shall comply with ANSI A118.8. Tile set and grouted with modified ...
Building Code 2021 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile > 2103.2.3.5 Modified Epoxy-Emulsion Mortar and Grout
2103.2.3.5 Masonry, Modified Epoxy-Emulsion Mortar and Grout
Modified epoxy-emulsion mortar and grout that are used to install ceramic tile shall comply with ANSI A118.8. Tile set and grouted with modified ...
Building Code 2018 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile > 2103.2.3.5 Modified Epoxy-Emulsion Mortar and Grout