• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3003.3.2.2 More Than Three Elevators

NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3003 Elevator Emergency Operations > 3003.3 Elevator in Readiness > 3003.3.2 Number of Elevators > 3003.3.2.2 More Than Three Elevators
JUMP TO FULL CODE CHAPTER
Where a floor is serviced by more than three elevator cars, at least three elevator cars with a total rated load capacity of not less than 6,000 pounds (2722 kg) shall be kept available for the sole use of the Fire Department. Such cars shall include not more than two cars that service all floors and at least one other car in another bank servicing that floor. If the total load capacity of all cars servicing the floor is less than 6,000 pounds (2722 kg), all such cars shall be kept available for sole use of the Fire Department.

Related Code Sections


3003.3.2.2 Elevators and Conveying Systems, More Than Three Elevators
Where a floor is serviced by more than three elevator cars, at least three elevator cars with a total rated load capacity of not less than 6,000 ...
NYC Building Code 2008 > 30 Elevators and Conveying Systems > 3003 Elevator Emergency Operations > 3003.3 Elevator in Readiness > 3003.3.2 Number of Elevators > 3003.3.2.2 More Than Three Elevators
3003.3.2.2 Elevators and Conveying Systems, More Than Three Elevators
Where a floor is serviced by more than three elevator cars, at least three elevator cars with a total rated load capacity of not less than 6,000 ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3003 Elevator Emergency Operations > 3003.3 Elevator in Readiness > 3003.3.2 Number of Elevators > 3003.3.2.2 More Than Three Elevators
3003.3.2.2 Elevators and Conveying Systems, More Than Three Elevators
Where a floor is serviced by more than three elevator cars, at least three elevator cars with a total rated load capacity of not less than 6,000 ...
NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3003 Emergency Operations > 3003.3 Elevator in Readiness > 3003.3.2 Number of Elevators > 3003.3.2.2 More Than Three Elevators
1109.6.1.1 Accessibility, Prior Code Buildings
building is less than 10,000 square feet (929 m 2 ) provided such LULA elevator is limited to a maximum rise of not more than 25 feet, serves not more ...
NYC Building Code 2014 > 11 Accessibility > 1109 Other Features and Facilities > 1109.6 Elevators > 1109.6.1 Limited-Use/Limited-Application (LULA) Elevators > 1109.6.1.1 Prior Code Buildings
1109.6 Accessibility, Elevators
feet (929 m 2 ) provided such LULA elevator serves not more than three contiguous floors and elevators are not otherwise required by Chapter 30 ...
NYC Building Code 2008 > 11 Accessibility > 1109 Other Features and Facilities > 1109.6 Elevators
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING