• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1103.4.3 More Than Five Stories

Fire Code 2018 of Colorado > 11 Construction Requirements for Existing Buildings > 1103 Fire Safety Requirements for Existing Buildings > 1103.4 Vertical Openings > 1103.4.3 More Than Five Stories
JUMP TO FULL CODE CHAPTER
In other than Group I-2 and I-3 occupancies, interior vertical openings connecting more than five stories shall be protected by 1-hour fire-resistance-rated construction.
Exceptions:
  1. Vertical opening protection is not required for Group R-3 occupancies.
  2. Vertical opening protection is not required for open parking garages.
  3. Vertical opening protection for escalators shall be in accordance with Section 1103.4.5, 1103.4.6 or 1103.4.7.
  4. Exit access stairways and ramps shall be in accordance with Section 1103.4.8.

Related Code Sections


1103.4.3 Construction Requirements for Existing Buildings, More Than Five Stories
In other than Group I-2 and I-3 occupancies, interior vertical openings connecting more than five stories shall be protected by 1-hour fire ...
Fire Code 2021 of Colorado > 11 Construction Requirements for Existing Buildings > 1103 Fire Safety Requirements for Existing Buildings > 1103.4 Vertical Openings > 1103.4.3 More Than Five Stories
1103.4.3 Construction Requirements for Existing Buildings, More Than Five Stories
In other than Group I-2 and I-3 occupancies, interior vertical openings connecting more than five stories shall be protected by 1-hour fire ...
Fire Code 2018 of Colorado > 11 Construction Requirements for Existing Buildings > 1103 Fire Safety Requirements for Existing Buildings > 1103.4 Vertical Openings > 1103.4.3 More Than Five Stories
714.5.1 Fire and Smoke Protection Features, Noncombustible Penetrating Items
Noncombustible penetrating items that connect not more than five stories are permitted, provided that the annular space is filled to resist ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.5 Nonfire-Resistance-Rated Assemblies > 714.5.1 Noncombustible Penetrating Items
714.6.1 Fire and Smoke Protection Features, Noncombustible Penetrating Items
Noncombustible penetrating items that connect not more than five stories are permitted, provided that the annular space is filled to resist ...
Building Code 2021 of Colorado > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.6 Nonfire-Resistance-Rated Assemblies > 714.6.1 Noncombustible Penetrating Items
714.6.1 Fire and Smoke Protection Features, Noncombustible Penetrating Items
Noncombustible penetrating items that connect not more than five stories are permitted, provided that the annular space is filled to resist ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.6 Nonfire-Resistance-Rated Assemblies > 714.6.1 Noncombustible Penetrating Items
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING