• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

42.10.2.2.9.5 Monthly Inspection

Fire Code 2018 of West Virginia > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.2 General Requirements > 42.10.2.2 Operations > 42.10.2.2.9* Aircraft Fueling Hose > 42.10.2.2.9.5 Monthly Inspection
JUMP TO FULL CODE CHAPTER
At least once each month the hose shall be completely extended and inspected as required in 42.10.2.2.9.4 and 42.10.2.2.9.5. [407:4.2.9.5]

42.10.2.2.9.5.1*

The hose couplings and the hose shall be examined for structural weakness or soft spots. [407:4.2.9.5.1]

42.10.2.2.9.5.2

With the hose completely extended, it shall be pressurized to the working pressure of the fueling equipment to which it is attached and checked for defects, such as abnormal twisting or blistering. [407:4.2.9.5.2]

Related Code Sections


42.10.2.2.9.5 Refueling, Monthly Inspection
At least once each month the hose shall be completely extended and inspected as required in 42.10.2.2.9.4 and 42.10.2.2.9.5. [ 407: 4.2.9.5 ...
Fire Code 2018 of West Virginia > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.2 General Requirements > 42.10.2.2 Operations > 42.10.2.2.9* Aircraft Fueling Hose > 42.10.2.2.9.5 Monthly Inspection
13.6.4.2.4.1.4 Fire Protection Systems,
Records for manual inspection shall be kept to demonstrate that at least the last 12 monthly inspections have been performed. [ 10: 7.2.4.1.4] ...
Fire Code 2018 of West Virginia > 13 Fire Protection Systems > 13.6 Portable Fire Extinguishers > 13.6.4 Inspection, Maintenance, and Recharging > 13.6.4.2 Inspection > 13.6.4.2.4 Inspection Record Keeping > 13.6.4.2.4.1 Manual Inspection Records > 13.6.4.2.4.1.4
13.6.4.2.4.1 Fire Protection Systems, Manual Inspection Records
inspection shall be kept to demonstrate that at least the last 12 monthly inspections have been performed. [ 10: 7.2.4.1.4] ...
Fire Code 2018 of West Virginia > 13 Fire Protection Systems > 13.6 Portable Fire Extinguishers > 13.6.4 Inspection, Maintenance, and Recharging > 13.6.4.2 Inspection > 13.6.4.2.4 Inspection Record Keeping > 13.6.4.2.4.1 Manual Inspection Records
13.6.4.2 Fire Protection Systems, Inspection
for manual inspection shall be kept to demonstrate that at least the last 12 monthly inspections have been performed. [ 10: 7.2.4.1.4 ...
Fire Code 2018 of West Virginia > 13 Fire Protection Systems > 13.6 Portable Fire Extinguishers > 13.6.4 Inspection, Maintenance, and Recharging > 13.6.4.2 Inspection
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING