405.2.4 Monitoring Well Design
JUMP TO FULL CODE CHAPTER
Not less than two wells shall extend to a depth of not less than 6 feet (1829 mm) below the ground surface and shall be not less than 3 feet (914 mm) below the designed system depth. However, with layered mottled soil over permeable unmottled soil, not less than one well shall terminate within the mottled layer. Monitoring at greater depths shall be required, where necessary, due to site conditions. The site evaluator shall determine the depth of the monitoring wells for each specific site. Depths shall be approved. The monitoring well shall be a solid pipe installed in a bore hole. The pipe size shall be not less than 1 inch (25 mm) and not greater than 4 inches (102 mm). The bore hole shall be not less than 4 inches (102 mm) and not greater than 8 inches (203 mm) larger than the pipe (see Appendix A, Figure A-2).
Related Code Sections
405.2.4 Site Evaluation and Requirements, Monitoring Well Design
) below the designed system depth. However, with layered mottled soil over permeable unmottled soil, not less than one well shall terminate within ...
Private Sewage Disposal Code 2018 of South Holland > 4 Site Evaluation and Requirements > 405 Soil Verification > 405.2 Monitoring Ground Water Levels > 405.2.4 Monitoring Well Design
405.2.4 Site Evaluation and Requirements, Monitoring Well Design
the designed system depth. However, with layered mottled soil over permeable unmottled soil, at least one well shall terminate within the mottled layer ...
Private Sewage Disposal Code 2012 of South Holland > 4 Site Evaluation and Requirements > 405 Soil Verification > 405.2 Monitoring Ground Water Levels > 405.2.4 Monitoring Well Design
Appendix A System Layout Illustrations
the outside diameter of observation well pipe size.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
FIGURE A-2 (SECTION 405.2.4)
MONITORING WELL ...
1306.2 Fuel Oil Piping and Storage, Test Wells
Test wells shall not be installed inside buildings. For outdoor service, test wells shall be equipped with a tight metal cover designed to discourage ...
Mechanical Code 2018 of South Holland > 13 Fuel Oil Piping and Storage > 1306 Oil Gauging > 1306.2 Test Wells
1306.2 Fuel Oil Piping and Storage, Test Wells
Test wells shall not be installed inside buildings. For outside service, test wells shall be equipped with a tight metal cover designed to discourage ...
Mechanical Code 2012 of South Holland > 13 Fuel Oil Piping and Storage > 1306 Oil Gauging > 1306.2 Test Wells