1910.1027(d)(3) Monitoring Frequency (Periodic Monitoring)
JUMP TO FULL CODE CHAPTER
If the initial monitoring or periodic monitoring reveals employee exposures to be at or above the action level, the employer shall monitor at a frequency and pattern needed to represent the levels of exposure of employees and where exposures are above the PEL to assure the adequacy of respiratory selection and the effectiveness of engineering and work practice controls. However, such exposure monitoring shall be performed at least every six months. The employer, at a minimum, shall continue these semi-annual measurements unless and until the conditions set out in paragraph (d)(3)(ii) are met.
If the initial monitoring or the periodic monitoring indicates that employee exposures are below the action level and that result is confirmed by the results of another monitoring taken at least seven days later, the employer may discontinue the monitoring for those employees whose exposures are represented by such monitoring.
Related Code Sections
1910.1027(d)(3) Toxic and Hazardous Substances, Monitoring Frequency (Periodic Monitoring)
If the initial monitoring or periodic monitoring reveals employee exposures to be at or above the action level, the employer shall monitor ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1027 Cadmium > 1910.1027(d) Exposure Monitoring > 1910.1027(d)(3) Monitoring Frequency (Periodic Monitoring)
1910.1047(d)(3) Toxic and Hazardous Substances, Monitoring Frequency (Periodic Monitoring)
If the monitoring required by paragraph (d)(2) of this section reveals employee exposure at or above the action level but at or below the 8-hour TWA ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1047 Ethylene Oxide > 1910.1047(d) Exposure Monitoring > 1910.1047(d)(3) Monitoring Frequency (Periodic Monitoring)
1910.1001(d)(3) Toxic and Hazardous Substances, Monitoring Frequency (Periodic Monitoring) and Patterns
After the initial determinations required by paragraph (d)(2)(i) of this section, samples shall be of such frequency and pattern as to represent ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(d) Exposure Monitoring > 1910.1001(d)(3) Monitoring Frequency (Periodic Monitoring) and Patterns
1910.1047(d)(3)(iv) Toxic and Hazardous Substances,
If the monitoring required by paragraph (d)(2)(i) of this section reveals employee exposure above the 15 minute excursion limit, the employer shall ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1047 Ethylene Oxide > 1910.1047(d) Exposure Monitoring > 1910.1047(d)(3) Monitoring Frequency (Periodic Monitoring) > 1910.1047(d)(3)(iv)
1910.1028(e)(3) Toxic and Hazardous Substances, Periodic Monitoring and Monitoring Frequency
If the monitoring required by paragraph (e)(2)(i) of this section reveals employee exposure at or above the action level but at or below the TWA ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(e) Exposure Monitoring > 1910.1028(e)(3) Periodic Monitoring and Monitoring Frequency