• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3310.8.1 Monitor Compliance

NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings > 3310.8 Site Safety Manager's and Coordinator's Responsibility > 3310.8.1 Monitor Compliance
JUMP TO FULL CODE CHAPTER
It is the responsibility of the site safety manager or coordinator to monitor compliance with the safety requirements of this chapter and to perform all other safety duties assigned by the owner or contractor to meet legal requirements.
  The site safety manager or coordinator) shall meet on a weekly basis with the designated representative of each subcontractor to ascertain that all subcontractors are complying with the applicable provisions of this chapter.

3310.8.1.1 Site Safety Manager or Coordinator Standpipe Inspection Responsibilities

The site safety manager or coordinator shall, at a minimum, in accordance with rules promulgated by the department, conduct daily checks to ensure that a standpipe system is available and in a state of readiness at all times for use by fire fighting personnel, by verifying:
  1. That valves are in place at each story below the construction floor;
  2. That standpipes are connected to a water source or siamese connection; and
  3. That siamese hose connections are free from obstruction and are marked by a red light and sign that reads, "Standpipe Siamese Connection."
   The site safety manager or coordinator shall also, in accordance with such rules, conduct weekly checks to verify that no breach exists by visually tracing the standpipe, including risers, cross connections and siamese connections. A record of all such inspections shall be maintained by such site safety manager or coordinator in a log book.
*Section BC 3310.8.1.1 was added by: Local Law 59 of 2009 — Update #25. This law has an effective date of Sept. 3, 2009.

Related Code Sections


3310.8.1 Safeguards During Construction or Demolition, Monitor Compliance
It is the responsibility of the site safety manager or coordinator to monitor compliance with the safety requirements of this chapter and to perform ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings > 3310.8 Site Safety Manager's and Coordinator's Responsibility > 3310.8.1 Monitor Compliance
§28-217.3 Enforcement, Compliance Monitoring
The SCO shall monitor the operations related to the circumstances and conditions that the commissioner has identified pursuant to section 28—217.2 ...
NYC General Admin. Provisions 2008 > 2 Enforcement > *217 Safety Compliance Officer > §28-217.3 Compliance Monitoring
§28-218.3 Enforcement, Compliance Monitoring
The SCO shall monitor the operations related to the circumstances and conditions that the commissioner has identified pursuant to section 28-218.2 ...
NYC General Admin. Provisions 2014 > 2 Enforcement > 218 Safety Compliance Officer > §28-218.3 Compliance Monitoring
§28-218.5 Enforcement, Compliance Monitoring
The SCO shall monitor the operations related to the circumstances and conditions that the commissioner has identified pursuant to section 28-218.2 ...
NYC General Admin. Provisions 2022 > 2 Enforcement > 218 Safety Compliance Officer > §28-218.5 Compliance Monitoring
3301.14 Safeguards During Construction or Demolition, Contractor Shall Inform Personnel
at the site, that the site safety manager or coordinator is responsible for monitoring compliance with laws and rules governing site safety; and shall ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3301 General > 3301.14 Contractor Shall Inform Personnel
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING