• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2104.1.2 Molded Cornices

Building Code 2018 of Illinois > 21 Masonry > 2104 Construction > 2104.1 Masonry Construction > 2104.1.2 Molded Cornices
JUMP TO FULL CODE CHAPTER
Unless structural support and anchorage are provided to resist the overturning moment, the center of gravity of projecting masonry or molded cornices shall lie within the middle one-third of the supporting wall. Terra cotta and metal cornices shall be provided with a structural frame of approved noncombustible material anchored in an approved manner.

Related Code Sections


2104.1.2 Masonry, Molded Cornices
Unless structural support and anchorage are provided to resist the overturning moment, the center of gravity of projecting masonry or molded ...
Building Code 2021 of Illinois > 21 Masonry > 2104 Construction > 2104.1 Masonry Construction > 2104.1.2 Molded Cornices
2104.1.2 Masonry, Molded Cornices
Unless structural support and anchorage are provided to resist the overturning moment, the center of gravity of projecting masonry or molded cornices ...
Building Code 2018 of Illinois > 21 Masonry > 2104 Construction > 2104.1 Masonry Construction > 2104.1.2 Molded Cornices
(3) Equipment for General Use, Molded Case Switch
A listed molded case switch ...
National Electrical Code 2017 of Illinois > 4 Equipment for General Use > 430 Motors, Motor Circuits, and Controllers > 430.109 Type > (A) General > (3) Molded Case Switch
(3) Equipment for General Use, Molded Case Switch
A listed molded case switch ...
National Electrical Code 2020 of Illinois > 4 Equipment for General Use > 430 Motors, Motor Circuits, and Controllers > 430.109 Type > (A) General > (3) Molded Case Switch
(3) Equipment for General Use, Molded Case Switch
A molded case switch rated in amperes shall be permitted as a controller for all motors ...
National Electrical Code 2020 of Illinois > 4 Equipment for General Use > 430 Motors, Motor Circuits, and Controllers > 430.83 Ratings > (A) General > (3) Molded Case Switch
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING