Light straw-clay walls shall be dry
to a moisture content of not more than 20 percent at a
depth of 4 inches (102 mm), as measured from each side
of the wall, prior to the application of finish on either side
of the wall. Moisture content shall be measured with a
moisture meter equipped with a probe that is designed for
use with baled straw or hay.
Related Code Sections
AR103.5.1 Light Straw-Clay Construction, Moisture Content of Light Straw-Clay Prior to Application of Finish
Light straw-clay walls shall be dry
to a moisture content of not more than 20 percent at a
depth of 4 inches (102 mm), as measured from each side ...
2015 Michigan Residential Code > R Light Straw-Clay Construction > AR103 Nonbearing Light Straw-Clay Construction > AR103.5 Wall Finishes > AR103.5.1 Moisture Content of Light Straw-Clay Prior to Application of Finish
AR103.4.3 Light Straw-Clay Construction, Moisture Barrier
An approved moisture barrier
shall separate the bottom of light straw-clay walls
from any masonry or concrete foundation or slab that
directly ...
2015 Michigan Residential Code > R Light Straw-Clay Construction > AR103 Nonbearing Light Straw-Clay Construction > AR103.4 Wall Construction > AR103.4.3 Moisture Barrier
AR103.5.4 Light Straw-Clay Construction, Bridging Across Dissimilar Substrates
Bridging shall be installed across dissimilar substrates
prior to the application of plaster. Acceptable bridging
materials include: expanded metal ...
2015 Michigan Residential Code > R Light Straw-Clay Construction > AR103 Nonbearing Light Straw-Clay Construction > AR103.5 Wall Finishes > AR103.5.4 Bridging Across Dissimilar Substrates
AS103.4 Strawbale Construction, Moisture Content
The moisture content of bales at
the time of application of the first coat of plaster or the installation of another finish shall not exceed 20 ...
AR103.4.7 Light Straw-Clay Construction, Openings in Walls
approved moisture barrier shall be installed at
window sills in light straw-clay walls prior to installation
of windows.
...