• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

4.505.3 Moisture Content of Building Materials

California Green Building Standards Code 2019 > 4 Residential Mandatory Measures > 4.505 Interior Moisture Control > 4.505.3 Moisture Content of Building Materials
JUMP TO FULL CODE CHAPTER
Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following:
  1. Moisture content shall be determined with either a probe-type or contact-type moisture meter. Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code.
  2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece to be verified.
  3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing.
Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure.

Related Code Sections


4.505.3 Residential Mandatory Measures, Moisture Content of Building Materials
Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members ...
California Green Building Standards Code 2019 > 4 Residential Mandatory Measures > 4.505 Interior Moisture Control > 4.505.3 Moisture Content of Building Materials
4.505.3 Residential Mandatory Measures, Moisture Content of Building Materials
Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members ...
California Green Building Standards Code 2016 > 4 Residential Mandatory Measures > 4.505 Interior Moisture Control > 4.505.3 Moisture Content of Building Materials
12-7A-1.3 Materials and Construction Methods for Exterior Wildfire Exposure, Referenced Documents
ASTM E 2257, Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies. ASTM D 4442, Test Methods for Direct Moisture Content ...
California Referenced Standards Code 2016 > 12-7A Materials and Construction Methods for Exterior Wildfire Exposure > 12-7A-1.3 Referenced Documents
12-7A-1.3 Materials and Construction Methods for Exterior Wildfire Exposure, Referenced Documents
ASTM E 2257, Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies. ASTM D 4442, Test Methods for Direct Moisture Content ...
California Referenced Standards Code 2019 > 12-7A Materials and Construction Methods for Exterior Wildfire Exposure > 12-7A-1.3 Referenced Documents
2303.1.9.2 Wood, Moisture Content
Where preservative-treated wood is used in enclosed locations where drying in service cannot readily occur, such wood shall be at a moisture content ...
California Building Code 2016 (Vol 1 & 2) > 23 Wood > 2303 Minimum Standards and Quality > 2303.1 General > 2303.1.9 Preservative-Treated Wood > 2303.1.9.2 Moisture Content
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING