2303.2.8 Moisture Content
JUMP TO FULL CODE CHAPTER
Fire-retardant-treated wood shall be dried to a moisture content of 19 percent or less for lumber and 15 percent or less for wood structural panels before use. For wood kiln-dried after treatment (KDAT), the kiln temperatures shall not exceed those used in kiln drying the lumber and plywood submitted for the tests described in Section 2303.2.5.1 for plywood and 2303.2.5.2 for lumber.
Related Code Sections
2303.1.9.2 Wood, Moisture Content
Where preservative-treated wood is used in enclosed locations where drying in service cannot readily occur, such wood shall be at a moisture ...
Building Code 2021 of Illinois > 23 Wood > 2303 Minimum Standards and Quality > 2303.1 General > 2303.1.9 Preservative-Treated Wood > 2303.1.9.2 Moisture Content
2303.1.9.2 Wood, Moisture Content
Where preservative-treated wood is used in enclosed locations where drying in service cannot readily occur, such wood shall be at a moisture ...
Building Code 2018 of Illinois > 23 Wood > 2303 Minimum Standards and Quality > 2303.1 General > 2303.1.9 Preservative-Treated Wood > 2303.1.9.2 Moisture Content
2109.2.1.3 Masonry, Moisture Content Requirements
Adobe units shall have a moisture content not exceeding 4 percent by weight ...
Building Code 2021 of Illinois > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe Construction > 2109.2.1 Unstabilized Adobe > 2109.2.1.3 Moisture Content Requirements
2109.2.1.3 Masonry, Moisture Content Requirements
Adobe units shall have a moisture content not exceeding 4 percent by weight ...
Building Code 2018 of Illinois > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe Construction > 2109.2.1 Unstabilized Adobe > 2109.2.1.3 Moisture Content Requirements
2304.9.4.1 Wood, General
Two-inch (51 mm) decking shall have a maximum moisture content of 15 percent. Decking shall be machined with a single tongue-and-groove pattern. Each ...
Building Code 2021 of Illinois > 23 Wood > 2304 General Construction Requirements > 2304.9 Lumber Decking > 2304.9.4 Two-Inch Sawn Tongue-And-Groove Decking > 2304.9.4.1 General