1926.1412(a) Modified Equipment
JUMP TO FULL CODE CHAPTER
Equipment that has had modifications or additions which affect the safe operation of the equipment (such as modifications or additions involving a safety device or operational aid, critical part of a control system, power plant, braking system, load-sustaining structural components, load hook, or in-use operating mechanism) or capacity must be inspected by a qualified person after such modifications/additions have been completed, prior to initial use. The inspection must meet all of the following requirements:
The inspection must assure that the modifications or additions have been done in accordance with the approval obtained pursuant to ยง 1926.1434 (Equipment modifications).
The inspection must include functional testing of the equipment.
Equipment must not be used until an inspection under this paragraph demonstrates that the requirements of paragraph (a)(1)(i) of this section have been met.
Related Code Sections
1926.1412(a) Cranes & Derricks in Construction, Modified Equipment
Equipment that has had modifications or additions which affect the safe operation of the equipment (such as modifications or additions involving ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1412 Inspections > 1926.1412(a) Modified Equipment
1926.1440(c)(9) Cranes & Derricks in Construction,
Section 14-2.2.2 ("Testing--Rated Load Test"), except that it applies only to equipment that has been altered or modified ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1440 Sideboom Cranes > 1926.1440(c) > 1926.1440(c)(9)
1926.1434(a)(2)(i) Cranes & Derricks in Construction,
A registered professional engineer who is a qualified person with respect to the equipment involved ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1434 Equipment Modifications > 1926.1434(a) > 1926.1434(a)(2) Manufacturer Refusal to Review Request > 1926.1434(a)(2)(i)
1926.403(j)(1) Electrical, General
Conductors and equipment used on circuits exceeding 600 volts, nominal, shall comply with all applicable provisions of paragraphs (a) through (g ...
OSHA 1926 Construction > K Electrical > 1926.403 General Requirements > 1926.403(j) Over 600 Volts, Nominal > 1926.403(j)(1) General
1926.1434(a) Cranes & Derricks in Construction,
Modifications or additions which affect the capacity or safe operation of the equipment are prohibited except where the requirements of paragraphs ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1434 Equipment Modifications > 1926.1434(a)