• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2501.1.1 Modifications to the "Ohio Plumbing Code

Ohio Residential Code 2013 > 25 Plumbing Systems > 2501.1 Plumbing Systems > 2501.1.1 Modifications to the "Ohio Plumbing Code
JUMP TO FULL CODE CHAPTER
The following sections of the "Ohio Plumbing Code" shall be deleted and replaced with the following language:
312.9 Shower liner test.
Deleted.417.5.2 Shower lining requirements.
Floors under shower compartments, except where prefabricated receptors have been provided, shall be lined and made water tight utilizing material complying with Sections 417.5.2.1 through 417.5.2.5. Such liners shall turn up on all sides at least 2 inches (51 mm) above the finished threshold level. Liners shall be recessed and fastened to an approved backing so as not to occupy the space required for wall covering, and shall not be nailed or perforated at any point less than 1 inch (25 mm) above the finished threshold. Liners shall be pitched one-fourth unit vertical in 12 units horizontal (2-percent slope) and shall be sloped toward the fixture drains and be securely fastened to the waste outlet at the seepage entrance, making a water-tight joint between the liner and the outlet.
Exceptions:
1. Floor surfaces under shower heads provided for rinsing laid directly on the ground are not required to comply with this section.
2. Where a sheet-applied, load-bearing, bonded, waterproof membrane is installed as the shower lining, the membrane shall not be required to be recessed.
1002.4 Trap seals.
Each fixture trap shall have a liquid seal of not less than 2 inches (51 mm) and not more than 4 inches (102 mm), or deeper for special designs relating to accessible fixtures. Where a trap seal is subject to loss by evaporation, a trap seal primer valve shall be installed. Trap seal primer valves shall connect to the trap at a point above the level of the trap seal. A trap seal primer valve shall conform to ASSE 1018 or ASSE 1044.
Exceptions:
1. Where a trap is supplied with water on a regular basis, a trap seal primer valve shall not be required.
2. A trap seal primer valve is not required in garage floor drains in one-, two- and three-family dwellings.

Related Code Sections


2501.1.1 Plumbing Systems, Modifications to the "Ohio Plumbing Code"
The following sections of the " Ohio Plumbing Code " shall be deleted and replaced with the following language: 417.5.2 Shower lining ...
2019 Residential Code of Ohio > 25 Plumbing Systems > 2501 Plumbing Systems > 2501.1 Plumbing Systems > 2501.1.1 Modifications to the "Ohio Plumbing Code"
2501.1.1 Plumbing Systems, Modifications to the "Ohio Plumbing Code
The following sections of the "Ohio Plumbing Code" shall be deleted and replaced with the following language: 312.9 Shower liner test ...
Ohio Residential Code 2013 > 25 Plumbing Systems > 2501.1 Plumbing Systems > 2501.1.1 Modifications to the "Ohio Plumbing Code
101.4.2 Administration, Plumbing
Chapters 4101:3-1 to 4101:3-13 of the Administrative Code, designated as the "Ohio Plumbing Code," shall apply to the installation, alterations ...
Ohio Building Code 2011 > 1 Administration > 101 General > 101.4 Referenced Codes > 101.4.2 Plumbing
101.4.2 Administration, Plumbing
Chapters 4101:3-1 to 4101:3-15 of the Administrative Code, designated as the "Ohio Plumbing Code," shall apply to the installation, alterations ...
Ohio Building Code 2017 > 1 Administration > 101 General > 101.4 Referenced Codes > 101.4.2 Plumbing
101.4.2 Scope and Administration, Plumbing
Chapters 4101:3-1 to 4101:3-13 of the Administrative Code, designated as the "Ohio Plumbing Code," shall apply to the installation, alterations ...
Ohio Mechanical Code 2011 > 1 Scope and Administration > 101 General > 101.4 Referenced Codes > 101.4.2 Plumbing
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING