62-824 Modifications to Passenger Queuing Shelters for Ferry or Water Taxi Docking Facilities
JUMP TO FULL CODE CHAPTER
In Community District 1 in the Borough of Brooklyn, the City Planning Commission may authorize a ferry passenger queueing shelter exceeding the dimensions set forth in paragraph (c)(1) of Section 62-813 (Docking facilities for ferries or water taxis in certain waterfront areas), provided that the Commission finds that:
(a) the public benefit derived from the proposed shelter merits the larger dimensions authorized;
(b) the proposed shelter utilizes the design standards set forth in paragraph (c)(1) of Section 62-813 regarding permitted support structures, materials, signage and roof construction to the greatest extent feasible;
(c) any modification to such provisions of Section 62-813 will not unduly limit views from the waterfront public access area; and
(d) the design of the proposed shelter will result in a quality structure that complements the waterfront public access area or the publicly accessible area of a waterfront zoning lot accommodating the ferry or water taxi docking facility.
Related Code Sections
1106.4 Recreational Facilities, Weather Shelters
A clear floor space 60 inches (1525 mm) minimum by 96 inches (2440 mm) minimum shall be provided within weather shelters ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 11 Recreational Facilities > 1106 Golf Facilities > 1106.4 Weather Shelters
Section G501 Flood-Resistant Construction, Modifications
greater than 5,000 a .
Power-generating stations, water treatment facilities for potable water, waste water treatment facilities and other public ...
805.3 Special Rooms and Spaces, Bus Shelters
Bus shelters shall provide a minimum clear floor space complying with Section 305 entirely within the shelter. Bus shelters shall ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 8 Special Rooms and Spaces > 805 Transportation Facilities > 805.3 Bus Shelters
1106.7.2 Accessibility, Medical Facilities
A passenger loading zone shall be provided at an accessible entrance to licensed medical and long-term care facilities where people receive physical ...
NYC Building Code 2008 > 11 Accessibility > 1106 Parking and Passenger Loading Facilities > 1106.7 Passenger Loading Zones > 1106.7.2 Medical Facilities
1106.7.2 Accessibility, Medical Facilities
A passenger loading zone shall be provided at an accessible entrance to licensed medical and long-term care facilities where people receive physical ...
NYC Building Code 2014 > 11 Accessibility > 1106 Parking and Passenger Loading Facilities > 1106.7 Passenger Loading Zones > 1106.7.2 Medical Facilities