1605A.4 Modifications to Load Combinations in ICC 300
JUMP TO FULL CODE CHAPTER
Modify Section
303.5.1 by adding Equation 3-1a and replacing Equation
3-2 as follows:
0.9D + 0.4L + 1.6Z
(Equation 3-1a)
1.2D + 1.6L + 1.6Rr
(Equation 3-2)
Modify Section
303.5.2 by adding Equation 3-3a, adding Equation 3-3b,
and replacing Equation 3-4 as follows:
D + 0.4L + Z
(Equation 3-3a)
0.6D + 0.3L + Z
(Equation 3-3b)
D + L + Rr
(Equation 3-4)
Related Code Sections
1605A.4 Structural Design, Modifications to Load Combinations in ICC 300
The text of ICC 300 shall be modified as indicated in Section
1605A.4.1 through 1605A.4.3 ...
California Building Code 2016 (Vol 1 & 2) > 16A Structural Design > 1605A Load Combinations > 1605A.4 Modifications to Load Combinations in ICC 300
1605A.4 Structural Design, Modifications to Load Combinations in ICC 300
Modify the text of ICC 300, Section 303.5.2 by adding
Equation 3-5a as follows:
D + 0.4L + Z (Equation 3-5a ...
California Building Code 2019 (Vol 1 & 2) > 16A Structural Design > 1605A Load Combinations > 1605A.4 Modifications to Load Combinations in ICC 300
1616.3.2 Structural Design, Modifications to Load Combinations in ICC 300
The text of ICC 300 shall be modified as indicated in Section
1616.3.2.1 through 1616.3.2.3 ...
California Building Code 2016 (Vol 1 & 2) > 16 Structural Design > 1616 Additional Requirements for Community Colleges [DSA-SS/CC] > 1616.3 Load Combinations > 1616.3.2 Modifications to Load Combinations in ICC 300
1617.3.2 Structural Design, Modifications to Load Combinations in ICC 300
Modify the text of ICC 300, Section 303.5.2 by adding
Equation 3-5a as follows:
D + 0.4L + Z (Equation 3-5a ...
California Building Code 2019 (Vol 1 & 2) > 16 Structural Design > 1617 Additional Requirements for Community Colleges [DSA-SS/CC] > 1617.3 Load Combinations > 1617.3.2 Modifications to Load Combinations in ICC 300
1605A.4.3 Structural Design, ICC 300, Section 303.5.3
Modify Section
303.5.3 as follows:
The uniform live load L used in Equation 3-2 and 3-4 may
be taken as zero when evaluating elements supporting ...
California Building Code 2019 (Vol 1 & 2) > 16A Structural Design > 1605A Load Combinations > 1605A.4 Modifications to Load Combinations in ICC 300 > 1605A.4.3 ICC 300, Section 303.5.3