Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

85-03 Modifications of Use Regulations

NYC Zoning Resolution > VIII Special Purpose Districts > 5 - Special United Nations Development District (U) > 85-00 General Purposes > 85-03 Modifications of Use Regulations
JUMP TO FULL CODE CHAPTER
In addition to the uses permitted in a C5-3 District, the uses and accessory uses set forth in this Section are hereby permitted in any development to be constructed in accordance with the general purposes and provisions of this Chapter, notwithstanding any other provision of this Resolution. All such commercial uses may be located in any mixed building and anywhere within such building without regard to Section 32-42 (Location Within Buildings).
(a)        Auditoriums, with unlimited capacity;
(b)        Automobile rental establishments;
(c)        Eating or drinking establishments, with entertainment and a capacity of more than 200 persons or establishments of any capacity with dancing; or
Eating or drinking establishments, with musical entertainment but not dancing, with a capacity of 200 persons or less;
(d)        Parking facilities, accessory, group, with a capacity of 380 parking spaces for automobiles solely for residences, hotels, foreign missions and United Nations related uses ;
(e)        Photographic developing or printing, without limitation on floor area per establishment;
(f)        Printing or publishing, without limitation on floor area per establishment;
(g)        Public parking lots, temporary, of no more than five years' duration or until such time as the development is completed, whichever is sooner;
(h)        Recreational uses, other;
(i)        Skating rinks, indoor;
(j)        Swimming pools, commercial;
(k)        Tennis courts, indoor;
(l)        Theaters, with unlimited capacity.

Related Code Sections


Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
NYC Building Code 2014 > G Flood-Resistant Construction > G501 Modifications
3311.4 Safeguards During Construction or Demolition, Modifications to ANSI A10.3
as follows: 4.2.2.1 Medium-velocity tools, indirect-acting (piston) type, as defined in Section 3, shall not be used ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.4 Modifications to ANSI A10.3
3311.4 Safeguards During Construction or Demolition, Modifications to ANSI A10.3
as follows: 4.2.2.1 Medium-velocity tools, indirect-acting (piston) type, as defined in Section 3, shall not be used ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.4 Modifications to ANSI A10.3
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
NYC Building Code 2008 > G Flood-Resistant Construction > G501 Modifications
1004.1.2 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.1, the commissioner may establish a lower ...
NYC Building Code 2014 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.2 Modifications
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING