// CODE SNIPPET
25-24 Modification of Requirements for Small Zoning Lots
JUMP TO FULL CODE CHAPTER
R6 R7 R8 R9 R10
In the districts indicated, for small zoning lots, the requirements set forth in Section 25-23 (Requirements Where Group Parking Facilities Are Provided) shall be modified in accordance with the provisions of this Section.
R6 R7 R8 R9 R10
In the districts indicated, for zoning lots of 10,000 or 15,000 square feet or less, the number of required accessory off-street parking spaces is as set forth in the following table:
REDUCED REQUIREMENTS FOR
SMALL ZONING LOTS
District | Lot Area | Parking Spaces Required as a Percent of Total Dwelling Units |
R6 R7-1* R7B | 10,000 square feet or less | 50 |
R7-1 R7A R7D R7X | 30 | |
R7-2 | 10,001 to 15,000 square feet | 30 |
R8** R9 R10 | 20 |
* Within lower density growth management areas in Community District 10, Borough of the Bronx
** In R8B Districts, the parking requirements may not be reduced.
R7-2 R8 R9 R10
In the districts indicated, the requirements set forth in Section 25-23 (Requirements where Group Parking Facilities Are Provided) shall be waived for zoning lots of 10,000 square feet or less, except in R8B Districts.
R3A R4-1
In the districts indicated, the requirements set forth in Section 25-22 (Requirements Where Individual Parking Facilities Are Provided) shall be waived for a single-family residence on an interior zoning lot that has a width along a street less than 25 feet.
Related Code Sections
Section G501 Flood-Resistant Construction, Modifications
-Zones unless specific elevation requirements are given in Section 3 of this standard.
See Table 1-1 or Table 1604.5 of the New York City Building Code ...
§28-104.7.18 Administration, Multiple Tax Lots on a Zoning Lot
of occupancy that indicates inconsistent metes and bounds to reflect the change in metes and bounds of the zoning lot, in accordance with the requirements ...
NYC General Admin. Provisions 2022 > 1 Administration > 104 Construction Documents > §28-104.7 Submittal of Construction Documents > §28-104.7.18 Multiple Tax Lots on a Zoning Lot
§28-118.3.5.1 Administration, Zoning Lot Change
Where metes and bounds of a zoning lot have been changed
after the effective date of this code for a building or open lot in existence prior ...
NYC General Admin. Provisions 2022 > 1 Administration > 118 Certificates of Occupancy > §28-118.3 Completed Buildings or Open Lots > §28-118.3.5 Existing Buildings or Open Lots Without Certificates of Occupancy > §28-118.3.5.1 Zoning Lot Change
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
506.2.2 General Building Heights and Areas; Separation of Occupancies, Open Space Limits
Such open space shall be either on the same zoning lot or dedicated for public use and shall be accessed from a street or approved fire lane ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 506 Area Modifications > 506.2 Frontage Increase > 506.2.2 Open Space Limits