105-431 Modification of Lot Coverage Controls
JUMP TO FULL CODE CHAPTER
For any development or enlargement on a Tier II site or within a steep slope or a steep slope buffer on a Tier I site, the City Planning Commission may authorize variations in the lot coverage controls set forth in Section 105-33.
In order to grant such authorization, the Commission shall find that:
- the development or enlargement is not feasible without such modification, or that the requested modification will permit a development or enlargement that satisfies the purpose of this Chapter;
- by allowing the permitted floor area in a building or buildings of lower height to cover more land, the preservation of hillsides having aesthetic value to the public would be assured, and that such preservation would not be possible by careful siting of a higher building containing the same permitted floor area on less land;
- such modification is the least modification required to achieve the purpose for which it is granted;
- the modification has minimal impact on the existing natural topography and vegetation and blends harmoniously with it;
- the modification will not disturb the drainage pattern and soil conditions of the area; and
- the modification does not impair the essential character of the surrounding area.
Related Code Sections
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
1004.1.2 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.1, the commissioner may establish a lower ...
NYC Building Code 2014 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.2 Modifications
1004.1.3.1 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.3, the commissioner may establish a lower ...
NYC Building Code 2022 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.3 Areas Without Fixed Seating > 1004.1.3.1 Modifications
1004.1.4 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.2, the commissioner may establish a lower ...
NYC Building Code 2008 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.4 Modifications