• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

13-35 Modification of Loading Berth Requirements

NYC Zoning Resolution > I General Provisions > 3 - Comprehensive Off-Street Parking and Loading Regulations in the Manhattan Core > 13-30 Off-Street Loading Regulations in the Manhattan Core > 13-35 Modification of Loading Berth Requirements
JUMP TO FULL CODE CHAPTER
The provisions of Sections 25-75 (Location of Access to the Street), 36-65 and 44-55 (Waiver of Requirements for All Zoning Lots Where Access Would Be Forbidden) shall be modified to allow the Commissioner of Buildings to reduce or waive the applicable loading berth requirements, provided that:
(a)        the zoning lot only has frontage upon a street, or portion thereof, where curb cuts or entrances and exits to accessory off-street loading berths are not permitted;
(b)        the zoning lot has frontage along a street where curb cuts accessing a loading berth are otherwise permitted, but there is no access to such zoning lot from the street due to the presence of:
(1)        a building, existing on May 8, 2013, containing residences ;
(2)        a non-residential building, existing on May 8, 2013, that is three or more stories in height; or
(3)        a building designated as a landmark or considered a contributing building in an Historic District designated by the Landmarks Preservation Commission; or
(c)        there are subsurface conditions, ventilation requirements from below-grade infrastructure or other site planning constraints that would make accommodating such loading berths infeasible.
In the case of paragraph (c), as set forth in this Section, the Commissioner shall require a loading berth of not less than 33 feet in depth, if such a berth can be accommodated in consideration of the relevant site restraints. The Commissioner of Buildings may request reports from licensed engineers or registered architects in considering such reduction or waiver.

Related Code Sections


1004.1.2 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.1, the commissioner may establish a lower ...
NYC Building Code 2014 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.2 Modifications
1004.1.4 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.2, the commissioner may establish a lower ...
NYC Building Code 2008 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.4 Modifications
1004.1.3.1 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.3, the commissioner may establish a lower ...
NYC Building Code 2022 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.3 Areas Without Fixed Seating > 1004.1.3.1 Modifications
Section G501 Flood-Resistant Construction, Modifications
For purposes of occupant load calculation, occupancies required by Table 1004.1.1 to use gross floor area calculations shall be permitted to use net ...
NYC Building Code 2014 > G Flood-Resistant Construction > G501 Modifications
Section G501 Flood-Resistant Construction, Modifications
to the exterior of the structure including hardware and signage, but shall not be required to comply with the occupant load calculations, unless ...
NYC Building Code 2008 > G Flood-Resistant Construction > G501 Modifications
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING