37-54 Modification of Design Standards of Pedestrian Circulation Spaces Within Existing Buildings
JUMP TO FULL CODE CHAPTER
The City Planning Commission may authorize a modification of any required minimum amount of pedestrian circulation space to be provided on wide street frontages and design standards, as indicated, for the following required pedestrian circulation spaces, to be provided within or under an existing building to remain on a zoning lot:
(a) Arcade: minimum width, minimum height, obstructions, minimum clear width between obstructions, minimum length, column sizes
(b) Building entrance recess area: minimum length, minimum depth from street line, minimum height, obstructions, clear space between obstructions and clear space between obstructions and building wall
(c) Corner arcade or corner circulation space: minimum depth, minimum width of clear path, minimum height, obstructions
(d) Through block connection: minimum width of unobstructed path, minimum height, through block level.
The Commission may authorize a modification of design standards for pedestrian circulation spaces when the following findings are met:
(1) a modification is needed because of the inherent constraints of the existing building;
(2) the modification is limited to the minimum needed because of the inherent constraints of the existing building; and
(3) the pedestrian circulation space as modified shall be equal in area, and substantially equivalent, to the required space in terms of quality, effectiveness and suitability for public use.
Related Code Sections
Section G501 Flood-Resistant Construction, Modifications to Referenced Standards
of floodwater to dry floodproofed spaces within the building.
3.3.2.3 Travel Distance. The path of travel from the alternate means of egress entrance door ...
NYC Building Code 2022 > G Flood-Resistant Construction > G501 Modifications to Referenced Standards
1104.3 Accessibility, Connected Spaces
, to accessible building entrances connecting accessible pedestrian walkways and the public way. Where only one accessible route is provided, the accessible ...
1104.3 Accessibility, Connected Spaces
of the building, to accessible building entrances connecting accessible pedestrian walkways and to the public way.
Exceptions:
Stories and mezzanines ...
1104.3 Accessibility, Connected Spaces
circulation paths within an employee work area and are not intended to remove the requirement of Section 1103.2.3 that employee work areas be designed ...
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...