A509.3.2 Modeling of Building Components
JUMP TO FULL CODE CHAPTER
Component initial stiffness shall be represented by a secant value defined by the effective yield point of the component. The effective initial stiffness shall be calculated using principles of mechanics, with due consideration of the effects of tensile cracking and compression strain.
Exception: Component effective initial stiffness may be calculated using the approximate values shown in Table A508.1.
Exception: Component effective initial stiffness may be calculated using the approximate values shown in Table A508.1.
The strength of building components shall be calculated using the procedures outlined in the appropriate section of the building code.
Exception: Component properties may be calculated using the principles of mechanics as verified by experimental results.
Exception: Component properties may be calculated using the principles of mechanics as verified by experimental results.
The deformability of building components shall be obtained from nonlinear load-deformation relationships that are appropriate for the component being considered. The nonlinear load-deformation relationship shall include information on the plastic deformation capacity at which lateral strength degrades, the plastic deformation capacity at which gravity-load resistance degrades, and the residual strength of the component after strength degradation.
The nonlinear load-deformation relationships of building components shall be determined from nonlinear analyses based on the principles of mechanics, experimental data or established values published in technical literature, as approved by the building official.
The nonlinear load-deformation relationships of building components shall be determined from nonlinear analyses based on the principles of mechanics, experimental data or established values published in technical literature, as approved by the building official.
Related Code Sections
A509.3.2 Earthquake Hazard Reduction in Existing Concrete Buildings and Concrete With Masonry Infill Buildings, Modeling of Building Components
The strength of building components shall be calculated using the procedures outlined ...
2010 Existing Building Code of NY > A5 Earthquake Hazard Reduction in Existing Concrete Buildings and Concrete With Masonry Infill Buildings > A509 Tier 3 Analysis Procedure > A509.3 Capacity Spectrum Analysis Procedure > A509.3.2 Modeling of Building Components
4.2.1.2.1 Administration and Enforcement,
components of the existing building. Modeling of the modified components of the existing building and addition shall employ the procedures of Section 11 ...
Part 2 of the NYStretch Energy Code 2020 > 4 Administration and Enforcement > 4.2 Compliance > 4.2.1 Compliance Paths > 4.2.1.2 Additions to Existing Buildings > 4.2.1.2.1
C3.1 Normative Appendix C Methodology for Building Envelope Trade-Off Option in Section 5.6, Simulation Program
shall include calculation methodologies for the building components being modeled ...
Part 2 of the NYStretch Energy Code 2020 > Normative Appendix C Methodology for Building Envelope Trade-Off Option in Section 5.6 > C3 Simulation General Requirements > C3.1 Simulation Program
11.5.1 Energy Cost Budget Method,
5. Building Envelope
All components of the building envelope in the proposed design shall be modeled as shown on architectural ...
Part 2 of the NYStretch Energy Code 2020 > 11 Energy Cost Budget Method > 11.5 Calculation of Design Energy Cost and Energy Cost Budget > 11.5.1
5.6.1 Building Envelope,
of the building envelope shown on architectural drawings or installed in existing buildings shall be modeled in the proposed design. The simulation program ...
Part 2 of the NYStretch Energy Code 2020 > 5 Building Envelope > 5.6 Building Envelope Trade-Off Option > 5.6.1