• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5704.3.7.2.1 Mixed Storage

Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.3 Container and Portable Tank Storage > 5704.3.7 Liquid Storage Rooms > 5704.3.7.2 Quantities and Arrangement of Storage > 5704.3.7.2.1 Mixed Storage
JUMP TO FULL CODE CHAPTER
Where two or more classes of liquids are stored in a pile or rack section, both of the following shall apply:
  1. The quantity in that pile or rack shall not exceed the smallest of the maximum quantities for the classes of liquids stored in accordance with Table 5704.3.6.3(2) or 5704.3.6.3(3).
  2. The height of storage in that pile or rack shall not exceed the smallest of the maximum heights for the classes of liquids stored in accordance with Table 5704.3.6.3(2) or 5704.3.6.3(3).

Related Code Sections


5104.8.1 Aerosols, Mixed Storage
Where aerosol cooking spray products are mixed with other higher-hazard aerosol products, the provided isolation, storage height restrictions ...
Fire Code 2021 of Colorado > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.8 Storage of Aerosol Cooking Spray Products > 5104.8.1 Mixed Storage
5104.8.1 Aerosols, Mixed Storage
Where aerosol cooking spray products are mixed with other higher-hazard aerosol products, the provided isolation, storage height restrictions ...
Fire Code 2018 of Colorado > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.8 Storage of Aerosol Cooking Spray Products > 5104.8.1 Mixed Storage
5704.3.7.2.1 Flammable and Combustible Liquids, Mixed Storage
height of storage in that pile or rack shall not exceed the smallest of the maximum heights for the classes of liquids stored in accordance with Table ...
Fire Code 2021 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.3 Container and Portable Tank Storage > 5704.3.7 Liquid Storage Rooms > 5704.3.7.2 Quantities and Arrangement of Storage > 5704.3.7.2.1 Mixed Storage
5704.3.7.2.1 Flammable and Combustible Liquids, Mixed Storage
height of storage in that pile or rack shall not exceed the smallest of the maximum heights for the classes of liquids stored in accordance with Table ...
Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.3 Container and Portable Tank Storage > 5704.3.7 Liquid Storage Rooms > 5704.3.7.2 Quantities and Arrangement of Storage > 5704.3.7.2.1 Mixed Storage
20.4.14.2 General Requirements for Storage,
Unless the requirements of 20.4.14.3 or 20.4.14.4 are met, mixed commodity storage shall be protected by the requirements for the highest classified ...
Standard for the Installation of Sprinkler Systems 2019 of Colorado > 20 General Requirements for Storage > 20.4* Commodity Classes > 20.4.14 Mixed Commodities > 20.4.14.2
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING