• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

506.5 Mixed Occupancy Area Determination

Building Code 2012 of South Holland > 5 General Building Heights and Areas > 506 Building Area Modifications > 506.5 Mixed Occupancy Area Determination
JUMP TO FULL CODE CHAPTER
The total allowable building area for buildings containing mixed occupancies shall be determined in accordance with the applicable provisions of this section. A single basement need not be included in the total allowable building area, provided such basement does not exceed the area permitted for a building with no more than one story above grade plane.

506.5.1 No More Than One Story Above Grade Plane

For buildings with no more than one story above grade plane and containing mixed occupancies, the total building area shall be determined in accordance with the applicable provisions of Section 508.1.

506.5.2 More Than One Story Above Grade Plane

For buildings with more than one story above grade plane and containing mixed occupancies, each story shall individually comply with the applicable requirements of Section 508.1. For buildings with more than three stories above grade plane, the total building area shall be such that the aggregate sum of the ratios of the actual area of each story divided by the allowable area of such stories based on the applicable provisions of Section 508.1 shall not exceed 3.

Related Code Sections


506.5 General Building Heights and Areas, Mixed Occupancy Area Determination
The total allowable building area for buildings containing mixed occupancies shall be determined in accordance with the applicable provisions ...
Building Code 2012 of South Holland > 5 General Building Heights and Areas > 506 Building Area Modifications > 506.5 Mixed Occupancy Area Determination
506.2.4.1 General Building Heights and Areas, Group H-2 or H-3 Mixed Occupancies
For a building containing Group H-2 or H-3 occupancies, the allowable area shall be determined in accordance with Section 508.4.2, with the sprinkler ...
Building Code 2018 of South Holland > 5 General Building Heights and Areas > 506 Building Area > 506.2 Allowable Area Determination > 506.2.4 Mixed-Occupancy, Multistory Buildings > 506.2.4.1 Group H-2 or H-3 Mixed Occupancies
506.2.4 General Building Heights and Areas, Mixed-Occupancy, Multistory Buildings
For a building containing Group H-2 or H-3 occupancies, the allowable area shall be determined in accordance with Section ...
Building Code 2018 of South Holland > 5 General Building Heights and Areas > 506 Building Area > 506.2 Allowable Area Determination > 506.2.4 Mixed-Occupancy, Multistory Buildings
415.8.2.1 Special Detailed Requirements Based on Use and Occupancy, Mixed Occupancies
Where the storage tank area is located in a building of two or more occupancies and the quantity of liquid exceeds the maximum allowable quantity ...
Building Code 2012 of South Holland > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.8 Group H-2 > 415.8.2 Flammable and Combustible Liquids > 415.8.2.1 Mixed Occupancies
415.9.1.1 Special Detailed Requirements Based on Occupancy and Use, Mixed Occupancies
Where the storage tank area is located in a building of two or more occupancies and the quantity of liquid exceeds the maximum allowable quantity ...
Building Code 2018 of South Holland > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.9 Group H-2 > 415.9.1 Flammable and Combustible Liquids > 415.9.1.1 Mixed Occupancies
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING