// CODE SNIPPET
1006.3.3.1 Mixed Occupancies
JUMP TO FULL CODE CHAPTER
Where one exit, or exit access stairway or ramp providing access to exits at other stories, is permitted to serve individual stories, mixed occupancies shall be permitted to be served by single exits provided each individual occupancy complies with the applicable requirements of Table 1006.3.3(1) or 1006.3.3(2) for that occupancy. Where applicable, cumulative occupant loads from adjacent occupancies shall be considered to be in accordance with the provisions of Section 1004.1. In each story of a mixed occupancy building, the maximum number of occupants served by a single exit shall be such that the sum of the ratios of the calculated number of occupants of the space divided by the allowable number of occupants indicated in Table 1006.3.3(2) for each occupancy does not exceed one. Where dwelling units are located on a story with other occupancies, the actual number of dwelling units divided by four plus the ratio from the other occupancy does not exceed one.
Related Code Sections
1006.3.3.1 Means of Egress, Mixed Occupancies
, mixed occupancies shall be permitted to be served by single exits provided each individual occupancy complies with the applicable requirements of Table ...
Building Code 2018 of Illinois > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.3 Single Exits > 1006.3.3.1 Mixed Occupancies
1006.3.4.1 Means of Egress, Mixed Occupancies
be considered to be in accordance with the provisions of Section 1004.1. In each story of a mixed occupancy building, the maximum number of occupants ...
Building Code 2021 of Illinois > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.4 Single Exits > 1006.3.4.1 Mixed Occupancies
1301.6.16 Performance Compliance Methods, Mixed Occupancies
Where a building has two or more occupancies that are not in the same occupancy classification, the separation between the mixed occupancies shall ...
Existing Building Code 2018 of Illinois > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.16 Mixed Occupancies
1301.6.16 Performance Compliance Methods, Mixed Occupancies
Where a building has two or more occupancies that are not in the same occupancy classification, the separation between the mixed occupancies shall ...
Existing Building Code 2021 of Illinois > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.16 Mixed Occupancies
415.9.1.1 Special Detailed Requirements Based on Occupancy and Use, Mixed Occupancies
Where the storage tank area is located in a building of two or more occupancies and the quantity of liquid exceeds the maximum allowable quantity ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.9 Group H-2 > 415.9.1 Flammable and Combustible Liquids > 415.9.1.1 Mixed Occupancies