// CODE SNIPPET
1910.213(r) Miscellaneous Woodworking Machines
JUMP TO FULL CODE CHAPTER
The feed rolls of roll type glue spreaders shall be guarded by a semicylindrical guard. The bottom of the guard shall come to within three-eighths inch of a plane formed by bottom or contact face of the feed roll where it touches the stock.
Drag saws shall be so located as to give at least a 4-foot clearance for passage when the saw is at the extreme end of the stroke; or if such clearance is not obtainable, the saw and its driving mechanism shall be provided with a standard enclosure.
For combination or universal woodworking machines each point of operation of any tool shall be guarded as required for such a tool in a separate machine.
The mention of specific machines in paragraphs (a) thru (q) and this paragraph (r) of this section, inclusive, is not intended to exclude other woodworking machines from the requirement that suitable guards and exhaust hoods be provided to reduce to a minimum the hazard due to the point of operation of such machines.
Related Code Sections
1910.213(r) Machinery and Machine Guarding, Miscellaneous Woodworking Machines
For combination or universal woodworking machines each point ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.213 Woodworking Machinery Requirements > 1910.213(r) Miscellaneous Woodworking Machines
1910.264(c)(4) Special Industries, Miscellaneous Machines and Equipment
[Reserved ...
OSHA 1910 General Industry > R Special Industries > 1910.264 Laundry Machinery and Operations > 1910.264(c) Point-Of-Operation Guards > 1910.264(c)(4) Miscellaneous Machines and Equipment
1910.263(i)(22) Special Industries, Doughnut Machines
Separate flues shall be provided, (i) for venting vapors from the frying section, and (ii) for venting products of combustion from the combustion ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(i) Miscellaneous Equipment > 1910.263(i)(22) Doughnut Machines
1910.213(k) Machinery and Machine Guarding, Tenoning Machines
Feed chains and sprockets of all double end tenoning machines shall be completely enclosed, except for that portion of chain used for conveying ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.213 Woodworking Machinery Requirements > 1910.213(k) Tenoning Machines
1910.213(p) Machinery and Machine Guarding, Sanding Machines
Feed rolls of self-feed sanding machines shall be protected with a semicylindrical guard to prevent the hands of the operator from coming in contact ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.213 Woodworking Machinery Requirements > 1910.213(p) Sanding Machines