§28-105.4.2 Minor Alterations and Ordinary Repairs

NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > *§28-105.4 Work Exempt From Permit > §28-105.4.2 Minor Alterations and Ordinary Repairs
JUMP TO FULL CODE CHAPTER
A permit shall not be required for minor alterations and ordinary repairs.

§28-105.4.2.1 Definitions

The following words and terms shall, for the purposes of this section 28-105.4.2 and as used elsewhere in this code, have the meanings shown herein.

MINOR ALTERATIONS. Minor changes or modifications in a building or any part thereof, excluding additions thereto, that do not in any way affect health or the fire or structural safety of the building or the safe use and operation of the service equipment therein. Minor alterations shall not include any of the work described as "work not constituting minor alterations or ordinary repairs."

ORDINARY REPAIRS. Replacements or renewals of existing work in a building, or of parts of the service equipment therein, with the same or equivalent materials or equipment parts, that are made in the ordinary course of maintenance and that do not in any way affect health or the fire or structural safety of the building or the safe use and operation of the service equipment therein. Ordinary repairs shall include the repair or replacement of any plumbing fixture, piping or faucets from any exposed stop valve to the inlet side of a trap. Ordinary repairs shall not include any of the work described as "work not constituting minor alterations or ordinary repairs."

WORK NOT CONSTITUTING MINOR ALTERATIONS OR ORDINARY REPAIRS. Minor alterations or ordinary repairs shall not include:

1. The cutting away of any load bearing or required fire rated wall, floor, or roof construction, or any portion thereof.

2. The removal, cutting, or modification of any beams or structural supports;

3. The removal, change, or closing of any required exit;

4. The addition, rearrangement, relocation, removal or replacement of any parts of the building affecting loading or exit requirements, or light, heat, ventilation, or elevator requirements or accessibility requirements, or any fire suppression or fire protection system;

5. Additions to, alterations of, or rearrangement, relocation, replacement, repair or removal of any portion of a standpipe or sprinkler system, water distribution system, house sewer, private sewer, or drainage system, including leaders, or any soil, waste or vent pipe, or any gas distribution system;

6. Any plumbing work other than the repair or replacement of plumbing fixtures, piping or faucets from the exposed stop valve to the inlet side of a trap;

7. The alteration or repair of a sign for which a permit is required; or

8. Any other work affecting health or the fire or structural safety of the building or the safe use and operation of the service equipment therein.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


§28-105.4.2 Administration, Minor Alterations and Ordinary Repairs
A permit shall not be required for minor alterations and ordinary repairs ...
NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > *§28-105.4 Work Exempt From Permit > §28-105.4.2 Minor Alterations and Ordinary Repairs
§28-105.4.2 Administration, Minor Alterations and Ordinary Repairs
A permit shall not be required for minor alterations and ordinary repairs ...
NYC General Admin. Provisions 2008 > 1 Administration > 105 Permits > §28-105.4 Work Exempt From Permit > §28-105.4.2 Minor Alterations and Ordinary Repairs
§27-992 Elevators and Conveyors, Alterations
four of subchapter one of this chapter. Minor alterations and ordinary repairs shall comply with the requirements of article five of subchapter one ...
NYC 1968 Code (Vol I) > 18 Elevators and Conveyors > 1 General > §27-992 Alterations
§28-410.8.6 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Supervision
with the provisions of this article.    Exception: The provisions of this section 28-410.8.6 shall not apply to minor alterations or ordinary ...
NYC General Admin. Provisions 2008 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > 410 Master Fire Suppression Piping Contractor License > §28-410.8 Master Fire Suppression Piping Contractor Business Required > §28-410.8.6 Supervision
§28-410.8.6 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Supervision
with the provisions of this article. Exception: The provisions of this section 28-410.8.6 shall not apply to minor alterations or ordinary repairs ...
NYC General Admin. Provisions 2014 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > 410 Master Fire Suppression Piping Contractor License > §28-410.8 Master Fire Suppression Piping Contractor Business Required > §28-410.8.6 Supervision
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US