• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P-1105.2 Minimum Vent Size

Philadelphia Plumbing Code > 11 Vents and Venting > P-1105 Ventilation of Branch or Horizontal Pipes > P-1105.2 Minimum Vent Size
JUMP TO FULL CODE CHAPTER
Any single water closet or pedestal urinal branch more than 8 feet in length or any single waste branch for fixtures other than water closets or pedestal urinals more than 12 feet in length shall have a vent sized at least one-half the diameter of the branch pipe. Depending on its length, the number of fixture units connected shall be in accordance with Table P-1110.4.

Figure P-1105.2

SINGLE WASTE BRANCHES IN EXCESS OF 8' - 0" and 12'-0" VENTING REQUIREMENTS


Figure P-1105.2a



* Refer to Chapters 9 and 11 For Sizing

CIRCUIT and LOOP VENTING FOR WALL HUNG WATER CLOSETS and SMALL FIXTURES


Figure P-1105.2b

* Refer to Chapters 9 and 11 For Sizing

CIRCUIT and LOOP VENTING FOR FLOOR MOUNTED CLOSETS and SMALL FIXTURES ABOVE

Related Code Sections


P-919.6.1 Vents, Minimum Vent Size
) in length shall have a vent sized at least one-half the diameter of the branch pipe. Depending on its length, the number of fixture units connected ...
Plumbing Code 2018 of Philadelphia > 9 Vents > P-919 Philadelphia Single-Stack Waste and Vent System > P-919.6 Fixture Venting > P-919.6.1 Minimum Vent Size
P-1105.2 Vents and Venting, Minimum Vent Size
or pedestal urinals more than 12 feet in length shall have a vent sized at least one-half the diameter of the branch pipe. Depending on its length ...
Philadelphia Plumbing Code > 11 Vents and Venting > P-1105 Ventilation of Branch or Horizontal Pipes > P-1105.2 Minimum Vent Size
504.3.8 Chimneys and Vents, Common Vent Minimum Size
The cross-sectional area of the common vent shall be equal to or greater than the cross-sectional area of the largest connector ...
Philadelphia Fuel Gas Code > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.3 Application of Multiple Appliance Vent Tables 504.3(1) Through 504.3(7) > 504.3.8 Common Vent Minimum Size
G2428.3.8 Fuel Gas, (504.3.8) Common Vent Minimum Size
The cross-sectional area of the common vent shall be equal to or greater than the cross-sectional area of the largest connector ...
Philadelphia Residential Code > 24 Fuel Gas > G2428 (504) Sizing of Category I Appliance Venting Systems > G2428.3 (504.3) Application of Multiple Appliance Vent Tables G2428.3(1) Through G2428.3(4) > G2428.3.8 (504.3.8) Common Vent Minimum Size
G2428.3.8 Fuel Gas, (504.3.8) Common Vent Minimum Size
The cross-sectional area of the common vent shall be equal to or greater than the cross-sectional area of the largest connector ...
Philadelphia Residential Code > 24 Fuel Gas > G2428 (504) Sizing of Category I Appliance Venting Systems > G2428.3 (504.3) Application of Multiple Appliance Vent Tables G2428.3(1) Through G2428.3(4) > G2428.3.8 (504.3.8) Common Vent Minimum Size
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING