R806.2 Minimum Vent Area
JUMP TO FULL CODE CHAPTER
The minimum net free ventilating area shall be 1/150 of the area of the vented space.
Exception: The minimum net free ventilation area shall be 1/300 of the vented space provided both of the following conditions are met:
- In Climate Zones 6, 7 and 8, a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling.
- Not less than 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not more than 3 feet (914 mm) below the ridge or highest point of the space, measured vertically. The balance of the required ventilation provided shall be located in the bottom one-third of the attic space. Where the location of wall or roof framing members conflicts with the installation of upper ventilators, installation more than 3 feet (914 mm) below the ridge or highest point of the space shall be permitted.
Related Code Sections
R806.2 Roof-Ceiling Construction, Minimum Vent Area
The minimum net free ventilating area shall be 1 / 150 of the area of the vented space. Exception: The minimum net free ventilation area shall ...
Residential Code 2021 of Colorado > 8 Roof-Ceiling Construction > R806 Roof Ventilation > R806.2 Minimum Vent Area
504.1 Chimneys and Vents, Definitions
The following definitions apply to the tables in this section. APPLIANCE CATEGORIZED VENT DIAMETER/AREA . The minimum vent area/diameter ...
Fuel Gas Code 2018 of Colorado > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.1 Definitions
G2428.1 Fuel Gas, (504.1) Definitions
The following definitions apply to the tables in this section: APPLIANCE CATEGORIZED VENT DIAMETER/AREA. The minimum vent area/diameter ...
Residential Code 2021 of Colorado > 24 Fuel Gas > G2428 (504) Sizing of Category I Appliance Venting Systems > G2428.1 (504.1) Definitions
G2428.1 Fuel Gas, (504.1) Definitions
The following definitions apply to the tables in this section. APPLIANCE CATEGORIZED VENT DIAMETER/AREA. The minimum vent area/diameter ...
Residential Code 2018 of Colorado > 24 Fuel Gas > G2428 (504) Sizing of Category I Appliance Venting Systems > G2428.1 (504.1) Definitions
319.7.5.1 General Requirements, Normal Vents
Normal vents shall be located above the maximum normal liquid line, and shall have a minimum effective area not smaller than the largest filling ...
Fire Code 2021 of Colorado > 3 General Requirements > 319 Mobile Food Preparation Vehicles > 319.7 Cooking Oil Storage Tanks > 319.7.5 Tank Venting > 319.7.5.1 Normal Vents