37-34 Minimum Transparency Requirements
JUMP TO FULL CODE CHAPTER
The ground floor level street wall along a primary street frontage or a designated retail street set forth in a Special Purpose District, as applicable, shall be glazed with transparent materials which may include show windows, transom windows or glazed portions of doors, except as set forth in Section 37-31 (Applicability).
Such transparent materials shall occupy at least 50 percent of the surface area of such ground floor level street wall between a height of two feet and 12 feet, or the height of the ground floor ceiling, whichever is higher, as measured from the adjoining sidewalk. Transparent materials provided to satisfy such 50 percent requirement shall not begin higher than 2 feet, 6 inches, above the level of the adjoining sidewalk, with the exception of transom windows, or portions of windows separated by mullions or other structural dividers, and shall have a minimum width of two feet. The maximum width of a portion of the ground floor level street wall without transparency shall not exceed 10 feet.
However, such transparency requirements shall not apply to portions of the ground floor level occupied by entrances or exits to accessory off-street parking facilities and public parking garages, where permitted, entryways to required loading berths, where permitted, entryways to subway stations, as applicable, or doors accessing emergency egress stairwells and passageways.
Related Code Sections
2410.1 Glass and Glazing, Requirement
Where the ground, floor or equivalent surface area in the path of approach to a fixed adjacent transparent sidelite from either side for a minimum ...
NYC Building Code 2022 > 24 Glass and Glazing > 2410 Marking of Transparent Doors and Fixed Adjacent Transparent Sidelites > 2410.1 Requirement
2410.2 Glass and Glazing, Requirement
Transparent doors and fixed adjacent sidelights shall be marked in accordance with Sections BC 2410.3 through 2410.5.
Exceptions:
One ...
NYC Building Code 2014 > 24 Glass and Glazing > 2410 Marking of Transparent Doors and Fixed Adjacent Transparent Sidelights > 2410.2 Requirement
2.22.4.6 Electric Elevators, Means for Determining Oil Level
Oil buffers shall be provided with means for determining that the oil level is within the maximum and minimum allowable limits. Transparent sight ...
Safety Code for Elevators and Escalators 2013 of New York City > 2 Electric Elevators > 2.22 Buffers and Bumpers > 2.22.4 Oil Buffers > 2.22.4.6 Means for Determining Oil Level
8.6.11.4 General Requirements, Cleaning of a Car and Hoistway Transparent Enclosure
The cleaning of the exterior of transparent car enclosures or transparent hoistway enclosures from inside the hoistway shall be performed only ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.6 Maintenance, Repair, Replacement, and Testing > 8.6.11 Special Provisions > 8.6.11.4 Cleaning of a Car and Hoistway Transparent Enclosure