• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-2029 Minimum Temperature to Be Maintained

§27 ‒ Housing Maintenance Code > 2 Maintenance, Services, and Utilities > 8 Heat and Hot Water > §27-2029 Minimum Temperature to Be Maintained
JUMP TO FULL CODE CHAPTER
   a.   During the period from October first through May thirty-first, centrally-supplied heat, in any dwelling in which such heat is required to be provided, shall be furnished so as to maintain, in every portion of such dwelling used or occupied for living purposes:
      (1)   between the hours of six a.m. and ten p.m., a temperature of at least sixty-eight degrees Fahrenheit whenever the outside temperature falls below fifty-five degrees; and
      (2)   between the hours of ten p.m. and six a.m., a temperature of at least fifty-five degrees Fahrenheit whenever the outside temperature falls below forty degrees.
   b.   During the period from October first through May thirty-first, all central heating systems required under this article shall be maintained free of any device which shall cause or which is capable of causing an otherwise operable central heating system to become incapable of providing the minimum requirements of heat or hot water as required by this article for any period of time. This subdivision shall not apply to any safety device required by law, or by a rule or regulation of any city agency, to be used in conjunction with a central heating system.

Related Code Sections


704.13.4 Fire and Smoke Protection Features, Temperature
A minimum ambient and substrate temperature of 40°F (4.44°C) shall be maintained during and for a minimum of 24 hours after the application ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.13 Sprayed Fire-Resistant Materials (SFRM) > 704.13.4 Temperature
2104.3.3 Masonry, Protection
shall be maintained at a temperature above 32°F (0°C) for at least 24 hours after being completed by using heated enclosures, electric heating blankets ...
NYC Building Code 2008 > 21 Masonry > 2104 Construction > 2104.3 Cold Weather Construction > 2104.3.3 Protection
704.13.4 Fire and Smoke Protection Features, Temperature
A minimum ambient and substrate temperature of 40°F (4.44°C) shall be maintained during and for not fewer than 24 hours after the application ...
NYC Building Code 2022 > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.13 Sprayed Fire-Resistant Materials (SFRM) > 704.13.4 Temperature
Section 309 General Regulations, Temperature Control
Interior spaces intended for human occupancy shall be provided with active or passive space-heating systems capable of maintaining a minimum indoor ...
NYC Mechanical Code 2008 > 3 General Regulations > 309 Temperature Control
Section 309 General Regulations, Temperature Control
Interior spaces intended for human occupancy shall be provided with active or passive space-heating systems capable of maintaining a minimum indoor ...
NYC Mechanical Code 2014 > 3 General Regulations > 309 Temperature Control
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING