• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.251(c)(13) Minimum Sling Lengths

OSHA 1926 Construction > H Materials Handling, Storage, Use, and Disposal > 1926.251 Rigging Equipment for Material Handling > 1926.251(c) Wire Rope > 1926.251(c)(13) Minimum Sling Lengths
JUMP TO FULL CODE CHAPTER

1926.251(c)(13)(i)

Cable laid and 6 × 19 and 6 × 37 slings shall have a minimum clear length of wire rope 10 times the component rope diameter between splices, sleeves or end fittings.

1926.251(c)(13)(iii)

Cable laid grommets, strand laid grommets and endless slings shall have a minimum circumferential length of 96 times their body diameter.

1926.251(c)(13)(ii)

Braided slings shall have a minimum clear length of wire rope 40 times the component rope diameter between the loops or end fittings.

Related Code Sections


1926.251(c)(13) Materials Handling, Storage, Use, and Disposal, Minimum Sling Lengths
Cable laid and 6 × 19 and 6 × 37 slings shall have a minimum clear length of wire rope 10 times the component rope diameter between splices, sleeves ...
OSHA 1926 Construction > H Materials Handling, Storage, Use, and Disposal > 1926.251 Rigging Equipment for Material Handling > 1926.251(c) Wire Rope > 1926.251(c)(13) Minimum Sling Lengths
1926.251(d)(4) Materials Handling, Storage, Use, and Disposal, Splicing
). Fiber rope slings shall have a minimum clear length of rope between eye splices equal to 10 times the rope ...
OSHA 1926 Construction > H Materials Handling, Storage, Use, and Disposal > 1926.251 Rigging Equipment for Material Handling > 1926.251(d) Natural Rope, and Synthetic Fiber > 1926.251(d)(4) Splicing
1926.251 Materials Handling, Storage, Use, and Disposal, Rigging Equipment for Material Handling
laid and 6 × 19 and 6 × 37 slings shall have a minimum clear length of wire rope 10 times the component rope diameter ...
OSHA 1926 Construction > H Materials Handling, Storage, Use, and Disposal > 1926.251 Rigging Equipment for Material Handling
1926.251(d) Materials Handling, Storage, Use, and Disposal, Natural Rope, and Synthetic Fiber
shall have a minimum clear length of rope between eye splices equal to 10 times the rope diameter ...
OSHA 1926 Construction > H Materials Handling, Storage, Use, and Disposal > 1926.251 Rigging Equipment for Material Handling > 1926.251(d) Natural Rope, and Synthetic Fiber
1926.551(c) Helicopters, Hoists, Elevators, and Conveyors, Slings and Tag Lines
Load shall be properly slung. Tag lines shall be of a length that will not permit their being drawn up into rotors. Pressed sleeve, swedged eyes ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.551 Helicopters > 1926.551(c) Slings and Tag Lines
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING