• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(A) Minimum Size of Conductors

National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 310 Conductors for General Wiring > 310.3 Conductors > (A) Minimum Size of Conductors
JUMP TO FULL CODE CHAPTER
The minimum size of conductors for voltage ratings up to and including 2000 volts shall be 14 AWG copper or 12 AWG aluminum or copper-clad aluminum, except as permitted elsewhere in this Code.

Related Code Sections


(A) Wiring Methods and Materials, Minimum Size of Conductors
The minimum size of conductors for voltage ratings up to and including 2000 volts shall be 14 AWG copper or 12 AWG aluminum or copper-clad aluminum ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 310 Conductors for General Wiring > 310.3 Conductors > (A) Minimum Size of Conductors
(A) Wiring Methods and Materials, Minimum Size of Conductors
The minimum size of conductors shall be as shown in Table 311.12(A), except as permitted elsewhere in this Code. Table 311.12(A) Minimum Size ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 311 Medium Voltage Conductors and Cable > 311.12 Conductors > (A) Minimum Size of Conductors
(B) Special Occupancies, Minimum Size of Conductors
Size 18 AWG or 16 AWG fixture wires as specified in 725.49 and flexible cords shall be permitted for the control and operating circuits of X-ray ...
National Electrical Code 2020 of Minnesota > 5 Special Occupancies > 517 Health Care Facilities > 517.74 Control Circuit Conductors > (B) Minimum Size of Conductors
620.12 Special Equipment, Minimum Size of Conductors
The minimum size of conductors, other than conductors that form an integral part of control equipment, shall be in accordance with 620.12(A) and (B ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.12 Minimum Size of Conductors
660.9 Special Equipment, Minimum Size of Conductors
Size 18 AWG or 16 AWG fixture wires, as specified in 725.49, and flexible cords shall be permitted for the control and operating circuits of X-ray ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 660 X-Ray Equipment > 660.9 Minimum Size of Conductors
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING