1030.2 Minimum Size
JUMP TO FULL CODE CHAPTER
Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m2).
Exception: The minimum net clear opening for grade-floor emergency escape and rescue openings shall be 5 square feet (0.46 m2).
The minimum net clear opening height dimension shall be 24 inches (610 mm). The minimum net clear opening width dimension shall be 20 inches (508 mm). The net clear opening dimensions shall be the result of normal operation of the opening.
Related Code Sections
1030.2 Means of Egress, Minimum Size
Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m 2 ). Exception: The minimum net clear ...
Building Code 2018 of Illinois > 10 Means of Egress > 1030 Emergency Escape and Rescue > 1030.2 Minimum Size
1031.3.1 Means of Egress, Minimum Size
Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m 2 ). Exception: The minimum net clear ...
Building Code 2021 of Illinois > 10 Means of Egress > 1031 Emergency Escape and Rescue > 1031.3 Emergency Escape and Rescue Openings > 1031.3.1 Minimum Size
(B) Wiring and Protection, Minimum Size
The conductors shall not be smaller than 8 AWG copper or 6 AWG aluminum or copper-clad aluminum. Exception: Conductors supplying only limited loads ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 230 Services > 230.23 Size and Rating > (B) Minimum Size
(B) Wiring and Protection, Minimum Size
The conductors shall not be smaller than 8 AWG copper or 6 AWG aluminum or copper-clad aluminum. Exception: Conductors supplying only limited loads ...
National Electrical Code 2020 of Illinois > 2 Wiring and Protection > 230 Services > 230.23 Size and Ampacity > (B) Minimum Size
(A) Wiring Methods and Materials, Minimum Size
transposing cable size into raceway size in 314.28(A)(1) and (A)(2), the minimum metric designator (trade size) raceway required for the number ...
National Electrical Code 2017 of Illinois > 3 Wiring Methods and Materials > 314 Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings; And Handhole Enclosures > 314.28 Pull and Junction Boxes and Conduit Bodies > (A) Minimum Size