R403.1.1 Minimum Size

Residential Code 2015 of Utah > 4 Foundations > R403 Footings > R403.1 General > R403.1.1 Minimum Size
JUMP TO FULL CODE CHAPTER
The minimum width, W, and thickness, T, for concrete footings shall be in accordance with Tables R403.1(1) through R403.1(3) and Figure R403.1(1) or R403.1.3, as applicable. The footing width shall be based on the load-bearing value of the soil in accordance with Table R401.4.1. Footing projections, P, shall be not less than 2 inches (51 mm) and shall not exceed the thickness of the footing. Footing thickness and projection for fireplaces shall be in accordance with Section R1001.2. The size of footings supporting piers and columns shall be based on the tributary load and allowable soil pressure in accordance with Table R401.4.1. Footings for wood foundations shall be in accordance with the details set forth in Section R403.2, and Figures R403.1(2) and R403.1(3).
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1030.2 Means of Egress, Minimum Size
Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m 2 ). Exception: The minimum net clear ...
Building Code 2015 of Utah > 10 Means of Egress > 1030 Emergency Escape and Rescue > 1030.2 Minimum Size
401.8 Gas Piping Installations, Minimum Sizes
Pipe utilized for the installation, extension and alteration of any piping system shall be sized to supply the full number of outlets ...
Fuel Gas Code 2015 of Utah > 4 Gas Piping Installations > 401 (IFGC) General > 401.8 Minimum Sizes
411.1.3.2 Gas Piping Installations, Minimum Size
Connectors shall have the capacity for the total demand of the connected appliance ...
Fuel Gas Code 2015 of Utah > 4 Gas Piping Installations > 411 (IFGC) Appliance and Manufactured Home Connections > 411.1 Connecting Appliances > 411.1.3 Connector Installation > 411.1.3.2 Minimum Size
504.2.2 Chimneys and Vents, Minimum Size
Where the vent size determined from the tables is smaller than the appliance draft hood outlet or flue collar, the smaller size shall ...
Fuel Gas Code 2015 of Utah > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.2 Application of Single-Appliance Vent Tables 504.2(1) Through 504.2(6) > 504.2.2 Minimum Size
722.2.4.1 Fire and Smoke Protection Features, Minimum Size
The minimum overall dimensions of reinforced concrete columns for fireresistance ratings of 1 hour to 4 hours for exposure to fire on all sides ...
Building Code 2015 of Utah > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.2 Concrete Assemblies > 722.2.4 Concrete Columns > 722.2.4.1 Minimum Size
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US