510.4.1.2 Minimum Signal Strength Out of the Building
JUMP TO FULL CODE CHAPTER
The minimum outbound signal strength shall be sufficient to provide usable voice communications throughout the coverage area as specified by the fire code official. The outbound signal level shall be sufficient to provide not less than a DAQ of 3.0 or an equivalent SINR applicable to the technology for either analog or digital signals.
Related Code Sections
510.4.1.2 Fire Service Features, Minimum Signal Strength Out of the Building
The minimum outbound signal strength shall be sufficient to provide usable voice communications throughout the coverage area as specified ...
Fire Code 2021 of Colorado > 5 Fire Service Features > 510 Emergency Responder Communication Coverage > 510.4 Technical Requirements > 510.4.1 Emergency Responder Communication Coverage System Signal Strength > 510.4.1.2 Minimum Signal Strength Out of the Building
510.4.1.2 Fire Service Features, Minimum Signal Strength Out of the Building
The minimum outbound signal strength shall be sufficient to provide usable voice communications throughout the coverage area as specified ...
Fire Code 2018 of Colorado > 5 Fire Service Features > 510 Emergency Responder Radio Coverage > 510.4 Technical Requirements > 510.4.1 Emergency Responder Communication Enhancement System Signal Strength > 510.4.1.2 Minimum Signal Strength Out of the Building
24.5.2.3 Emergency Communications Systems (ECS), Signal Strength
A minimum inbound signal strength of —95 dBm, or other signal strength as required by the authority having jurisdiction, shall be provided throughout ...
National Fire Alarm and Signaling Code 2013 of Colorado > 24 Emergency Communications Systems (ECS) > 24.5 Two-Way, In-Building Emergency Communications Systems > 24.5.2* Two-Way Radio Communications Enhancement Systems > 24.5.2.3 Signal Strength
24.5.2.3.2 Emergency Communications Systems (ECS), Outbound
A minimum outbound signal strength of —95 dBm at the donor site, or other signal strength as required by the authority having jurisdiction, shall ...