Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

317.5 Minimum Seismic Design Performance Levels for Structural and Nonstructural Components

California Existing Building Code 2019 > 3 Provisions for All Compliance Methods > 317 Earthquake Evaluation and Design for Retrofit of Existing Buildings > 317.5 Minimum Seismic Design Performance Levels for Structural and Nonstructural Components
JUMP TO FULL CODE CHAPTER
Following the notations of ASCE 41, the seismic requirements for design and assessment are based upon a prescribed Earthquake Hazard Level (BSE-1N, BSE-2N, BSE-1E, BSE-R or BSE-C), a specified structural performance level (S-1 through S-5) and a nonstructural performance level (N-A through NE). The minimum seismic performance criteria are given in Table 317.5 according to the Building Regulatory Authority and the Risk Category as determined in Chapter 16 of the California Building Code or by the regulatory authority. The building shall be evaluated in accordance with a Tier 3 Systematic Evaluation and Retrofit per ASCE 41 Chapter 6 for both the Level 1 and Level 2 performance levels, and the more restrictive requirements shall apply.
Exception: If the floor area of an addition is greater than the larger of 50 percent of the floor area of the original building or 1,000 square feet (93 m2), then the Table 317.5 entries for BSE-R (or BSE-1E) and BSE-C are replaced by BSE-1N and BSE-2N, respectively.
TABLE 317.5
SEISMIC PERFORMANCE REQUIREMENTS BY BUILDING REGULATORY AUTHORITY AND RISK CATEGORY.
Building Regulatory Authority Risk Category PERFORMANCE CRITERIA
Level 1 Level 2
State-Owned [BSC] I, II, III BSE-R, S-3, N-C BSE-C, S-5, N-D
State-Owned [BSC] IV BSE-R, S-2, N-B BSE-C, S-4, N-D
Division of the State Architect - [DSA-SS] I BSE-1N, S-3, N-B BSE-2N, S-5, N-D
Division of the State Architect - [DSA-SS] II, III BSE-1N, S-2, N-B BSE-2N, S-4, N-D
Division of the State Architect - [DSA-SS] IV BSE-1N, S-2, N-A BSE-2N, S-4, N-D
Division of the State Architect - [DSA-SS/CC] I, II BSE-1E, S-3, N-C BSE-2N, S-5, N-D
Division of the State Architect - [DSA-SS/CC] III BSE-1E, S-3, N-B BSE-2N, S-5, N-D
Division of the State Architect - [DSA-SS/CC] IV BSE-1E, S-2, N-B BSE-2N, S-4, N-D
  1. ASCE 41 provides acceptance criteria (e.g., m, rotation) for Immediate Occupancy (S1), Life Safety (S3), and Collapse Prevention (S5), and specifies in Sections 2.3.1.2.1 and 2.3.1.4.1 the method to interpolate values for S-2 and S-4, respectively. For nonstructural components, N-A corresponds to the Operational level, N-B to the Position Retention, N-C to the Life Safety level, N-D to the Hazards Reduced, and N-E to the Not Considered. When evaluating for the Hazards Reduced Nonstructural Performance Level, the requirements need not be greater than what would be required by ASCE 7 nonstructural provisions for new construction.
  2. Buildings evaluated and retrofitted to meet the requirements for a new building, Chapter 16 of the California Building Code, in accordance with the exception in Section 319.1, are deemed to meet the seismic performance requirements of this section.

Related Code Sections


317.5 Provisions for All Compliance Methods, Minimum Seismic Design Performance Levels for Structural and Nonstructural Components
Following the notations of ASCE 41, the seismic requirements for design and assessment are based upon a prescribed Earthquake Hazard Level (BSE-1N ...
California Existing Building Code 2016 > 3 Provisions for All Compliance Methods > 317 Earthquake Evaluation and Design for Retrofit of Existing Buildings > 317.5 Minimum Seismic Design Performance Levels for Structural and Nonstructural Components
317.5 Provisions for All Compliance Methods, Minimum Seismic Design Performance Levels for Structural and Nonstructural Components
, BSE-2N, BSE-1E, BSE-R or BSE-C), a specified structural performance level (S-1 through S-5) and a nonstructural performance level (N-A through NE). The ...
California Existing Building Code 2019 > 3 Provisions for All Compliance Methods > 317 Earthquake Evaluation and Design for Retrofit of Existing Buildings > 317.5 Minimum Seismic Design Performance Levels for Structural and Nonstructural Components
3104F.5 [SLC] Marine Oil Terminals, Nonstructural Components
weight of nonstructural components shall be included in the dead load of the structure, per Section 3103F.2 ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3104F Seismic Analysis and Structural Performance > 3104F.5 Nonstructural Components
303A.3.4 Provisions for All Compliance Methods, Performance Objectives of Performance-Based Methods
) Structural Performance Level (S-3) as defined in Section 2.3.1.3 at Basic Safety Earthquake 2N (BSE-2N) Seismic Hazard Level; and The nonstructural ...
California Existing Building Code 2019 > 3A Provisions for All Compliance Methods > 303A Structural Design Loads and Evaluation and Design Procedures > 303A.3 Additions, Alterations, Repairs and Seismic Retrofit to Existing Buildings or Structures > 303A.3.4 Performance Objectives of Performance-Based Methods
3104F.5.2 [SLC] Marine Oil Terminals, Seismic Assessment
new (N) nonstructural components, nonbuilding structures and building structures and their supports and attachments, seismic evaluation and design ...
California Building Code 2019 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3104F Seismic Analysis and Structural Performance > 3104F.5 Nonstructural Components, Nonbuilding Structures and Building Structures > 3104F.5.2 Seismic Assessment
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING